Vickers by Danfoss592923

592923

DG4S4 Series Solenoid Operated Directional Valve
Item #101977820
  • D05 Double Solenoid Operated Valve
  • 115 VAC - 50 Hz
  • Lead Wires w/Terminal Box
  • No Coil
  • 3-Position Spring Centered
  • All Ports Blocked
  • w/Indicator Lights
  • None
  • Design Level 50
+ Show More + Show Less
Vickers by Danfoss592923
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • D05 Double Solenoid Operated Valve
  • 115 VAC - 50 Hz
  • Lead Wires w/Terminal Box
  • No Coil
  • 3-Position Spring Centered

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Valve Type Standard-Duty
Mechanical Options Code None
Flow Direction Code 4
Coil Rating Code None
Operation Solenoid Operated
Pressure Port Check Valve Pressure N/A
Design No. 50
Voltage & Frequency 115 VAC – 50 Hz
Electrical Options None
Pressure [Max] 3000 psi
Surge Suppressor/Damper None
Rated Flow [Max] 20 gal/min
Indicator Lights Yes
Response Type Standard Response
Cycle Rate [Max] N/A
Electrical Connection Lead Wires w/ Terminal Box
Center Position All Ports Blocked
Function 3-Position Spring Centered
Port T Pressure Rating 1000 psi
Electrical Options Code LW
NFPA Size D05
Spool Code 2
Overrides No Overrides
Port Restrictor Plugs None
Spool Spring Arrangement Code C
Pilot/Drain None
Pilot Valve Type N/A
Mechanical Options None
Actuator Type Solenoid
Solenoid Air Gap Code None
Solenoid Double
Coil Type No Coil
Seal Material Buna-N
Crossover All Ports Blocked
Reducer Module N/A
AC/DC AC
Weight 10.0 LB