- Flow Control Valve
- Flow Divider/Combiner Type
- FDC1-16 Series
- 12 gal/min Minimum Flow
- 47 gal/min Maximum Flow
description
- Pressure-compensated, spool-type, screw-in, flow divider/combiner cartridge. This valve is used in the dividing mode. It will take the inlet flow (port 3) and split the flow according to the ratio specified, regardless of system pressure to ports 2 and 4. In the combining mode this valve will take the inlet flows from ports 2 and 4 and combine them into port 3 according to the ratio specified.
caution
- Steel housings must be used for operating pressures above 210 bar (3,000 psi)
| Temperature Range [Max] | 248 °F |
| Seal Kit Viton | 889638 |
| Type | Flow Divider/Combiner |
| Style | Spool |
| Operation | Direct Acting |
| Installation | Screw-in Cartridge |
| Recommend Filtration Level | 18/16/13 microns |
| Divider Flow | 24 gal/min |
| Cavity | C-16-4 |
| Flow [Min] | 12 gal/min |
| Seal Kit Buna | 889634 |
| Series | FDC1-16 |
| Body Type | 10 |
| Port Type | Cartridge Only |
| Pressure [Max] | 3000 psi |
| Housing Material | Aluminum |
| Valve Material | Cartridge only |
| No. of Valve Ports | 4 |
| No. of Housing Ports | 4 |
| Temperature Range [Min] | -40 °F |
| Model No. | FDC1-16-0-44 |
| Valve Torque into Cavity | 108 to 122 Nm |
| Leakage | Standard |
| Manufacturer Part No. | FDC1-16-0-44 |
| Flow [Max] | 47 gal/min |
| Seal Material | Buna-N |
| Weight | 0.78 LB |