Vickers D05 Solenoid Valve
Item #101909043
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-362358
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Series 02 two-stage directional valves are designed to meet the requirements of high performance, precision industrial hydraulic systems operating at pressure to 210 bar (3,000 psi) and flows to 130 l/min (34 U.S. gpm), depending on spool type.

features

  • Tapered main spool lands which permit faster operation with less hydraulic shock
  • Advanced design pilot valves provide reduced power consumption without any sacrifice of valve performance
  • Quiet, long-life solenoids can be quickly replaced without disturbing the hydraulic circuitry for easy maintenance
Coil Type 1/2 in NPT Thread Wiring Housing
Electrical Connection Wired Terminal Block
Response Type Code None
Body Material Gray Iron
Crossover All Ports Blocked, or P & B Blocked, A to T
Temperature Range [Min] -0.4 °F
Model No. DG5S4-02-3C-M-FTWL-B6-30
Actuator Type Solenoid
Manual Override Plain Override
Seal Material Buna-N
Mounting Subplate/Manifold Mount
Valve Type Standard-Duty
Solenoid Double
Overrides Plain Override Solenoid Ends
Coil Type Code F
No. of Stages Two Stage
Port T Pressure Rating 2285 psi
Pilot/Drain External Drain
Pressure [Max] 3000 psi
Spool Spring Arrangement Code C
EN Code None
Pilot Pressure Code None
Port Restrictor Plug Code None
Electrical Options None
AC/DC AC
Pilot Pressure [Max] 3000 psi
Surge Suppressor/Damper None
Spool Code 3
Function 3-Position Spring Centered
Actuation Identification Solenoid A, Solenoid B
Coil Rating Code B
Pressure Port Check Valve Code None
Reducer Module N/A
Fluid Cleanliness 19/17/14 micron
NFPA Size D05
Housing Code W
Indicator Lights Yes
Leakage Standard Performance
Solenoid Energization Code None
Manual Override Option Code None
Response Type Standard Response
Pilot Drain Code None
Pilot Valve Type N/A
Spool Indicator Switch Code None
Spool Control Modification Code None
Temperature Range [Max] 150.8 °F
Port Restrictor Plugs None
Pilot Pressure [Min] 75 psi
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Assembly Code None
Tank Port Rating 2321
Design No. 30
Electrical Connector Code T
Mounting Screw Option Code None
Operation Solenoid Operated
Electrical Options Code None
Solenoid Indicator Lights Code L
Pilot Valve Tank Pressure Rating Code 6
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position P & B Blocked, A to T
Rated Flow [Max] 30 gal/min
Weight 13.0 LB