Skip to content Skip to navigation menu
Vickers by Danfoss02-362358

02-362358

Vickers D05 Solenoid Valve
Item #101909043
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-362358
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Series 02 two-stage directional valves are designed to meet the requirements of high performance, precision industrial hydraulic systems operating at pressure to 210 bar (3,000 psi) and flows to 130 l/min (34 U.S. gpm), depending on spool type.

features

  • Tapered main spool lands which permit faster operation with less hydraulic shock
  • Advanced design pilot valves provide reduced power consumption without any sacrifice of valve performance
  • Quiet, long-life solenoids can be quickly replaced without disturbing the hydraulic circuitry for easy maintenance
Function 3-Position Spring Centered
Crossover All Ports Blocked, or P & B Blocked, A to T
Pressure Port Check Valve Pressure N/A
EN Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Control Modification Code None
Seal Material Buna-N
Electrical Connection Wired Terminal Block
Housing Code W
Leakage Standard Performance
Manual Override Option Code None
Port Restrictor Plugs None
Port Restrictor Plug Code None
NFPA Size D05
Assembly Code None
Mounting Screw Option Code None
Coil Type 1/2 in NPT Thread Wiring Housing
Center Position P & B Blocked, A to T
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Body Material Gray Iron
Coil Type Code F
Mechanical Options None
Response Type Standard Response
Model No. DG5S4-02-3C-M-FTWL-B6-30
Mounting Subplate/Manifold Mount
Pilot Valve Type N/A
Actuation Identification Solenoid A, Solenoid B
Rated Flow [Max] 30 gal/min
Overrides Plain Override Solenoid Ends
Manual Override Plain Override
Pilot Pressure [Min] 75 psi
Electrical Options Code None
AC/DC AC
Operation Solenoid Operated
Temperature Range [Max] 150.8 °F
Coil Rating Code B
Spool Code 3
Solenoid Energization Code None
Surge Suppressor/Damper None
Solenoid Double
Solenoid Indicator Lights Code L
Port T Pressure Rating 2285 psi
Pilot Pressure Code None
Tank Port Rating 2321
Design No. 30
Pilot Drain Code None
Indicator Lights Yes
Pressure Port Check Valve Code None
Temperature Range [Min] -0.4 °F
Response Type Code None
Valve Type Standard-Duty
Pilot/Drain External Drain
No. of Stages Two Stage
Pilot Valve Tank Pressure Rating Code 6
Electrical Connector Code T
Pilot Pressure [Max] 3000 psi
Reducer Module N/A
Electrical Options None
Spool Spring Arrangement Code C
Actuator Type Solenoid
Pressure [Max] 3000 psi
Weight 13.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison