- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Coil Type Code | F |
| Model No. | DG5V-8-H-3C-T-K-M-FTWL-B-10 |
| Surge Suppressor/Damper Code | None |
| Performance | High Performance |
| Coil Rating Code | B |
| Solenoid Energization Code | None |
| Pilot Pressure Code | None |
| NFPA Size | D08 |
| Pressure Port Check Valve Pressure | 5 psi |
| Fluid Cleanliness | 19/17/14 micron |
| Spool Control Modification Code | None |
| Mechanical Options | None |
| Pressure Port Check Valve Code | K |
| Overrides | Plain Override Solenoid Ends |
| Pilot Valve Type | CETOP 3, High Performance |
| Spool Code | 3 |
| Indicator Lights | Yes |
| Port T Pressure Rating | 5000 psi |
| Valve Type | Standard-Duty |
| Actuator Type | Solenoid |
| Body Material | Ductile Iron |
| Mechanical Options Code | None |
| Spool Indicator Switch Code | None |
| Solenoid | Double |
| Housing Code | W |
| Pressure [Max] | 5000 psi |
| Electrical Options Code | None |
| Crossover | All Ports Blocked, or P & B Blocked, A to T |
| Leakage | High Performance |
| Spool Spring Arrangement Code | C |
| Actuation Identification | Solenoid A, Solenoid B |
| Function | 3-Position Spring Centered |
| Reducer Module Code | None |
| Surge Suppressor/Damper | None |
| Manual Override Option Code | None |
| Pilot Valve Type Code | H |
| Electrical Options | None |
| Pilot Drain Code | T |
| Center Position | P & B Blocked, A to T |
| Electrical Connector Code | T |
| Seal Material | Buna-N |
| Compatible Fluids | Petroleum Oil |
| Manual Override | Plain Override |
| Port Restrictor Plugs | None |
| Port Restrictor Plug Code | None |
| Temperature Range [Min] | -40 °F |
| Response Type Code | None |
| No. of Stages | Two Stage |
| EN Code | None |
| Operation | Pilot Operated |
| Design No. | 10 |
| AC/DC | AC |
| Temperature Range [Max] | 230 °F |
| Gauge Port | SAE-4 |
| Response Type | Standard Response |
| Electrical Connection | Wired Terminal Block |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Tank Port Rating | 5000 |
| Mounting | Subplate/Manifold Mount |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Reducer Module | No |
| Gauge Ports Code | None |
| Rated Flow [Max] | 175 gal/min |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Solenoid Indicator Lights Code | L |
| Weight | 35.0 LB |