- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Mechanical Options Code | None |
Mechanical Options | None |
Pilot Valve Type | CETOP 3, High Performance |
Seal Material | Buna-N |
Housing Code | W |
Operation | Pilot Operated |
Electrical Options | None |
Performance | High Performance |
EN Code | None |
Solenoid Energization Code | None |
Body Material | Ductile Iron |
Pressure Port Check Valve Pressure | 5 psi |
Design No. | 10 |
Pressure Port Check Valve Code | K |
Spool Code | 3 |
Port T Pressure Rating | 5000 psi |
Surge Suppressor/Damper | None |
Pilot Valve Type Code | H |
Gauge Ports Code | None |
Spool Control Modification Code | None |
Crossover | All Ports Blocked, or P & B Blocked, A to T |
Port Restrictor Plug Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Leakage | High Performance |
Manual Override | Plain Override |
Pilot/Drain | Internal Pilot/Internal Drain |
Indicator Lights | Yes |
Tank Port Rating | 5000 |
Electrical Connector Code | T |
Actuator Type | Solenoid |
Mounting | Subplate/Manifold Mount |
Pilot Pressure Code | None |
Pressure [Max] | 5000 psi |
Spool Indicator Switch Code | None |
Rated Flow [Max] | 175 gal/min |
Coil Type Code | F |
Temperature Range [Max] | 230 °F |
Fluid Cleanliness | 19/17/14 micron |
Response Type | Standard Response |
Electrical Options Code | None |
No. of Stages | Two Stage |
Center Position | P & B Blocked, A to T |
Pilot Drain Code | T |
Valve Type | Standard-Duty |
Reducer Module | No |
Gauge Port | SAE-4 |
Temperature Range [Min] | -40 °F |
Surge Suppressor/Damper Code | None |
Model No. | DG5V-8-H-3C-T-K-M-FTWL-B-10 |
Solenoid | Double |
Function | 3-Position Spring Centered |
Solenoid Indicator Lights Code | L |
Electrical Connection | Wired Terminal Block |
Actuation Identification | Solenoid A, Solenoid B |
Spool Spring Arrangement Code | C |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Port Restrictor Plugs | None |
Manual Override Option Code | None |
AC/DC | AC |
Coil Rating Code | B |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
NFPA Size | D08 |
Compatible Fluids | Petroleum Oil |
Overrides | Plain Override Solenoid Ends |
Response Type Code | None |
Reducer Module Code | None |
Weight | 35.0 LB |