Vickers D08 Solenoid Valve
Item #101975621
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337216
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Pilot Drain Code None
Operation Pilot Operated
Spool Indicator Switch Code None
Surge Suppressor/Damper None
Mechanical Options Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Solenoid Indicator Lights Code L
NFPA Size D08
Pressure Port Check Valve Code None
Temperature Range [Min] -40 °F
AC/DC AC
Spool Spring Arrangement Code C
Mechanical Options Adjust Pilot Chokes on Both Ends
Gauge Port SAE-4
Function 3-Position Spring Centered
Actuator Type Solenoid
Port Restrictor Plug Code None
Port T Pressure Rating 5000 psi
Manual Override Plain Override
Spool Control Modification Code 2
Solenoid Double
Model No. DG5V-8-S-0C-2-E-M-FTWL-B-10
Fluid Cleanliness 19/17/14 micron
No. of Stages Two Stage
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot/Drain External Pilot/External Drain
Reducer Module No
Gauge Ports Code None
Port Restrictor Plugs None
Body Material Ductile Iron
Pilot Pressure Code E
Coil Type Code F
EN Code None
Leakage Standard Performance
Actuation Identification Solenoid A, Solenoid B
Spool Code 0
Mounting Subplate/Manifold Mount
Manual Override Option Code None
Electrical Connection Wired Terminal Block
Temperature Range [Max] 230 °F
Performance Standard Performance
Electrical Connector Code T
Overrides Plain Override Solenoid Ends
Seal Material Buna-N
Center Position All Ports Open
Housing Code W
Compatible Fluids Petroleum Oil
Design No. 10
Response Type Standard Response
Pilot Valve Type CETOP 3, Standard Performance
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Tank Port Rating 5000
Reducer Module Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Options None
Indicator Lights Yes
Response Type Code None
Rated Flow [Max] 175 gal/min
Crossover All Ports Open
Electrical Options Code None
Pilot Valve Type Code S
Coil Rating Code B
Solenoid Energization Code None
Pressure [Max] 5000 psi
Weight 35.0 LB