Vickers by Danfoss02-337216

02-337216

Vickers D08 Solenoid Valve
Item #101975621
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337216
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Electrical Connection Wired Terminal Block
Mechanical Options Adjust Pilot Chokes on Both Ends
Rated Flow [Max] 175 gal/min
Pilot Valve Type CETOP 3, Standard Performance
Temperature Range [Min] -40 °F
Gauge Port SAE-4
Actuator Type Solenoid
Function 3-Position Spring Centered
Reducer Module No
Actuation Identification Solenoid A, Solenoid B
Gauge Ports Code None
Electrical Connector Code T
Spool Code 0
Crossover All Ports Open
Manual Override Option Code None
Mechanical Options Code None
EN Code None
Overrides Plain Override Solenoid Ends
Electrical Options None
Tank Port Rating 5000
Spool Spring Arrangement Code C
Port T Pressure Rating 5000 psi
Reducer Module Code None
Solenoid Indicator Lights Code L
Response Type Standard Response
Spool Control Modification Code 2
Indicator Lights Yes
Fluid Cleanliness 19/17/14 micron
Coil Type Code F
NFPA Size D08
Compatible Fluids Petroleum Oil
Coil Rating Code B
Surge Suppressor/Damper Code None
Body Material Ductile Iron
Electrical Options Code None
Housing Code W
Manual Override Plain Override
Model No. DG5V-8-S-0C-2-E-M-FTWL-B-10
Pilot Pressure Code E
No. of Stages Two Stage
Pilot Valve Type Code S
Performance Standard Performance
Port Restrictor Plugs None
Pressure Port Check Valve Pressure N/A
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Response Type Code None
Pressure [Max] 5000 psi
Leakage Standard Performance
Operation Pilot Operated
Voltage & Frequency 110/120 VAC - 50/60 Hz
Solenoid Energization Code None
Solenoid Double
Port Restrictor Plug Code None
Surge Suppressor/Damper None
Temperature Range [Max] 230 °F
Design No. 10
Valve Type Standard-Duty
Spool Indicator Switch Code None
Pressure Port Check Valve Code None
Pilot/Drain External Pilot/External Drain
Pilot Drain Code None
Mounting Subplate/Manifold Mount
Center Position All Ports Open
AC/DC AC
Weight 35.0 LB