Vickers by Danfoss02-337168

02-337168

Vickers D08 Solenoid Valve
Item #101975622
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337168
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Electrical Options None
Center Position P to T, A & B Blocked
Valve Type Standard-Duty
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
Reducer Module No
Crossover All Ports Open, Restricted
Pressure Port Check Valve Pressure N/A
Actuator Type Solenoid
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
EN Code None
Port T Pressure Rating 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Drain Code None
Compatible Fluids Petroleum Oil
Pressure [Max] 5000 psi
Surge Suppressor/Damper None
Coil Rating Code B
Solenoid Double
No. of Stages Two Stage
Pilot/Drain Internal Pilot/External Drain
Operation Pilot Operated
Coil Type Code F
Port Restrictor Plugs None
Function 3-Position Spring Centered
Manual Override Plain Override
Response Type Standard Response
Performance Standard Performance
Model No. DG5V-8-S-8C-2-VM-FW-B-10
NFPA Size D08
Mechanical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Design No. 10
Housing Code W
Pressure Port Check Valve Code None
Leakage Standard Performance
Reducer Module Code None
Temperature Range [Min] -40 °F
Fluid Cleanliness 19/17/14 micron
Seal Material Buna-N
Mounting Subplate/Manifold Mount
Electrical Connector Code None
Mechanical Options Adjust Pilot Chokes on Both Ends
Tank Port Rating 5000
Actuation Identification Solenoid A, Solenoid B
Manual Override Option Code None
Pilot Valve Type CETOP 3, Standard Performance
Spool Code 8
Electrical Options Code None
Body Material Ductile Iron
Gauge Ports Code None
Solenoid Energization Code V
Overrides Plain Override Solenoid Ends
Electrical Connection No Connector
Temperature Range [Max] 230 °F
Response Type Code None
Indicator Lights No
Spool Indicator Switch Code None
Rated Flow [Max] 175 gal/min
Spool Control Modification Code 2
Gauge Port SAE-4
AC/DC AC
Solenoid Indicator Lights Code None
Pilot Valve Type Code S
Spool Spring Arrangement Code C
Pilot Pressure Code None
Weight 35.0 LB