Vickers by Danfoss02-337168

02-337168

Vickers D08 Solenoid Valve
Item #101975622
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337168
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
NFPA Size D08
Gauge Ports Code None
Port Restrictor Plugs None
Solenoid Double
Operation Pilot Operated
Pilot Valve Type Code S
Leakage Standard Performance
Spool Control Modification Code 2
Temperature Range [Min] -40 °F
Model No. DG5V-8-S-8C-2-VM-FW-B-10
Pilot Pressure Code None
Manual Override Plain Override
Housing Code W
Crossover All Ports Open, Restricted
Indicator Lights No
Gauge Port SAE-4
No. of Stages Two Stage
AC/DC AC
Spool Indicator Switch Code None
Mechanical Options Code None
Compatible Fluids Petroleum Oil
Pilot/Drain Internal Pilot/External Drain
Temperature Range [Max] 230 °F
Electrical Options None
Electrical Connector Code None
Electrical Connection No Connector
Solenoid Energization Code V
Manual Override Option Code None
Pilot Drain Code None
Electrical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuator Type Solenoid
Reducer Module Code None
Port T Pressure Rating 5000 psi
Actuation Identification Solenoid A, Solenoid B
Mechanical Options Adjust Pilot Chokes on Both Ends
Response Type Standard Response
Performance Standard Performance
Coil Type Code F
Spool Spring Arrangement Code C
Rated Flow [Max] 175 gal/min
Overrides Plain Override Solenoid Ends
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
EN Code None
Pressure Port Check Valve Code None
Pilot Valve Type CETOP 3, Standard Performance
Surge Suppressor/Damper Code None
Mounting Subplate/Manifold Mount
Reducer Module No
Function 3-Position Spring Centered
Fluid Cleanliness 19/17/14 micron
Center Position P to T, A & B Blocked
Design No. 10
Response Type Code None
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Seal Material Buna-N
Tank Port Rating 5000
Port Restrictor Plug Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Spool Code 8
Coil Rating Code B
Valve Type Standard-Duty
Body Material Ductile Iron
Weight 35.0 LB