- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Reducer Module | No |
| Spool Indicator Switch Code | None |
| Solenoid Indicator Lights Code | None |
| Overrides | Plain Override Solenoid Ends |
| Surge Suppressor/Damper | None |
| Mounting | Subplate/Manifold Mount |
| Gauge Port | SAE-4 |
| Surge Suppressor/Damper Code | None |
| Manual Override | Plain Override |
| Spool Code | 6 |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Reducer Module Code | None |
| Manual Override Option Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Solenoid Energization Code | None |
| Mechanical Options | None |
| Compatible Fluids | Petroleum Oil |
| Pressure Port Check Valve Pressure | N/A |
| Indicator Lights | No |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| AC/DC | AC |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Fluid Cleanliness | 19/17/14 micron |
| Response Type Code | None |
| Performance | High Performance |
| Leakage | Standard Performance |
| Operation | Pilot Operated |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Electrical Connection | No Connector |
| Pressure Port Check Valve Code | None |
| Valve Type | Standard-Duty |
| Seal Material | Buna-N |
| Design No. | 10 |
| Response Type | Standard Response |
| Gauge Ports Code | None |
| Housing Code | W |
| No. of Stages | Two Stage |
| Pilot/Drain | External Pilot/Internal Drain |
| Rated Flow [Max] | 175 gal/min |
| Port Restrictor Plugs | None |
| Spool Spring Arrangement Code | C |
| Mechanical Options Code | None |
| Electrical Options Code | None |
| Port Restrictor Plug Code | None |
| NFPA Size | D08 |
| Pilot Pressure Code | None |
| EN Code | None |
| Center Position | P Blocked, A & B to T |
| Pilot Valve Type Code | H |
| Electrical Connector Code | None |
| Pressure [Max] | 5000 psi |
| Crossover | P Blocked, A or B to T |
| Pilot Drain Code | None |
| Model No. | DG5V-8-H-6C-M-FW-B-10 |
| Port T Pressure Rating | 5000 psi |
| Spool Control Modification Code | None |
| Coil Rating Code | B |
| Coil Type Code | F |
| Solenoid | Double |
| Actuator Type | Solenoid |
| Body Material | Gray Iron |
| Function | 3-Position Spring Centered |
| Tank Port Rating | 5000 |
| Electrical Options | None |
| Weight | 35.0 LB |