- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
Reducer Module | No |
Mechanical Options Code | None |
Solenoid Indicator Lights Code | None |
Overrides | Plain Override Solenoid Ends |
Response Type | Standard Response |
Mechanical Options | None |
Port T Pressure Rating | 5000 psi |
Model No. | DG5V-8-H-6C-M-FW-B-10 |
EN Code | None |
Solenoid | Double |
AC/DC | AC |
Compatible Fluids | Petroleum Oil |
Tank Port Rating | 5000 |
Coil Type Code | F |
Actuator Type | Solenoid |
Body Material | Gray Iron |
Spool Indicator Switch Code | None |
No. of Stages | Two Stage |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Crossover | P Blocked, A or B to T |
Port Restrictor Plug Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Electrical Options | None |
Electrical Options Code | None |
Reducer Module Code | None |
Manual Override | Plain Override |
Function | 3-Position Spring Centered |
Pressure Port Check Valve Pressure | N/A |
Operation | Pilot Operated |
Valve Type | Standard-Duty |
Leakage | Standard Performance |
Pilot Valve Type | CETOP 3, High Performance |
Mounting | Subplate/Manifold Mount |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Coil Rating Code | B |
Pressure [Max] | 5000 psi |
Seal Material | Buna-N |
Electrical Connector Code | None |
Response Type Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Center Position | P Blocked, A & B to T |
Pilot Pressure Code | None |
Pilot/Drain | External Pilot/Internal Drain |
NFPA Size | D08 |
Surge Suppressor/Damper Code | None |
Port Restrictor Plugs | None |
Pressure Port Check Valve Code | None |
Rated Flow [Max] | 175 gal/min |
Solenoid Energization Code | None |
Spool Control Modification Code | None |
Pilot Valve Type Code | H |
Surge Suppressor/Damper | None |
Housing Code | W |
Manual Override Option Code | None |
Fluid Cleanliness | 19/17/14 micron |
Pilot Drain Code | None |
Indicator Lights | No |
Performance | High Performance |
Electrical Connection | No Connector |
Gauge Port | SAE-4 |
Design No. | 10 |
Spool Code | 6 |
Gauge Ports Code | None |
Spool Spring Arrangement Code | C |
Weight | 35.0 LB |