- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Surge Suppressor/Damper | None |
| Pilot Pressure Code | None |
| Pilot Valve Type Code | S |
| Overrides | Plain Override Solenoid Ends |
| Spool Spring Arrangement Code | C |
| NFPA Size | D08 |
| Pilot/Drain | External Pilot/Internal Drain |
| Function | 3-Position Spring Centered |
| Pressure [Max] | 5000 psi |
| Port Restrictor Plugs | None |
| Gauge Ports Code | None |
| Solenoid | Double |
| Solenoid Indicator Lights Code | L |
| Actuator Type | Solenoid |
| Indicator Lights | Yes |
| Port T Pressure Rating | 5000 psi |
| Design No. | 10 |
| Surge Suppressor/Damper Code | None |
| Rated Flow [Max] | 185 gal/min |
| Operation | Pilot Operated |
| Model No. | DG5V-8-S-4C-VM-FTWL-B-10 |
| AC/DC | AC |
| Coil Type Code | F |
| Coil Rating Code | B |
| Pressure Port Check Valve Pressure | N/A |
| Spool Control Modification Code | None |
| Center Position | Tandem P to T |
| Reducer Module | N/A |
| Electrical Options Code | None |
| Seal Material | Buna-N |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Pressure Port Check Valve Code | None |
| Electrical Options | None |
| Gauge Port | SAE-4 |
| Mechanical Options Code | None |
| Tank Port Rating | 5000 |
| Electrical Connector Code | T |
| Spool Code | 4 |
| Crossover | All Ports Blocked |
| EN Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Pilot Drain Code | None |
| Electrical Connection | Wired Terminal Block |
| Valve Type | Standard-Duty |
| Mechanical Options | None |
| Manual Override Option Code | None |
| Port Restrictor Plug Code | None |
| Spool Indicator Switch Code | None |
| Manual Override | Plain Override |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Housing Code | W |
| Reducer Module Code | None |
| Response Type | Standard Response |
| Solenoid Energization Code | V |
| Response Type Code | None |
| Weight | 35.0 LB |