Vickers D08 Solenoid Valve
Item #101979712
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329141
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Reducer Module N/A
Response Type Standard Response
Housing Code W
Function 3-Position Spring Centered
Mechanical Options Code None
AC/DC AC
Electrical Options None
Gauge Port SAE-4
Actuator Type Solenoid
Pressure [Max] 5000 psi
Operation Pilot Operated
Solenoid Energization Code V
Mechanical Options None
EN Code None
Response Type Code None
Center Position Tandem P to T
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Model No. DG5V-8-S-4C-VM-FTWL-B-10
Spool Control Modification Code None
Design No. 10
Spool Code 4
Pilot Pressure Code None
Crossover All Ports Blocked
Port T Pressure Rating 5000 psi
Pilot Valve Type Code S
Surge Suppressor/Damper None
Spool Spring Arrangement Code C
Pilot Valve Type CETOP 3, Standard Performance
Electrical Options Code None
Electrical Connection Wired Terminal Block
NFPA Size D08
Rated Flow [Max] 185 gal/min
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Code None
Manual Override Option Code None
Electrical Connector Code T
Valve Type Standard-Duty
Solenoid Indicator Lights Code L
Reducer Module Code None
Manual Override Plain Override
Pilot Drain Code None
Coil Rating Code B
Surge Suppressor/Damper Code None
Indicator Lights Yes
Overrides Plain Override Solenoid Ends
Spool Indicator Switch Code None
Port Restrictor Plugs None
Port Restrictor Plug Code None
Pressure Port Check Valve Pressure N/A
Tank Port Rating 5000
Pilot/Drain External Pilot/Internal Drain
Gauge Ports Code None
Solenoid Double
Coil Type Code F
Weight 35.0 LB