Vickers by Danfoss02-329141

02-329141

Vickers D08 Solenoid Valve
Item #101979712
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329141
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Crossover All Ports Blocked
Coil Type Code F
Seal Material Buna-N
Coil Rating Code B
Pilot Pressure Code None
Reducer Module Code None
Indicator Lights Yes
Function 3-Position Spring Centered
Port Restrictor Plug Code None
Mechanical Options Code None
Electrical Connector Code T
Actuator Type Solenoid
Pilot Drain Code None
Gauge Port SAE-4
Manual Override Plain Override
Port Restrictor Plugs None
Operation Pilot Operated
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot/Drain External Pilot/Internal Drain
Port T Pressure Rating 5000 psi
Solenoid Energization Code V
NFPA Size D08
Model No. DG5V-8-S-4C-VM-FTWL-B-10
Spool Code 4
Mechanical Options None
Manual Override Option Code None
Overrides Plain Override Solenoid Ends
AC/DC AC
Pilot Valve Type Code S
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Tank Port Rating 5000
Surge Suppressor/Damper Code None
Rated Flow [Max] 185 gal/min
Solenoid Indicator Lights Code L
Spool Spring Arrangement Code C
Spool Control Modification Code None
Pressure Port Check Valve Code None
Valve Type Standard-Duty
Response Type Code None
Design No. 10
Electrical Connection Wired Terminal Block
Reducer Module N/A
Solenoid Double
Gauge Ports Code None
Electrical Options Code None
Electrical Options None
Center Position Tandem P to T
Surge Suppressor/Damper None
Housing Code W
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Response Type Standard Response
EN Code None
Pilot Valve Type CETOP 3, Standard Performance
Pressure Port Check Valve Pressure N/A
Weight 35.0 LB