Vickers D10 Solenoid Valve
Item #102086115
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-321801
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Port Restrictor Plugs None
Coil Type Code F
Temperature Range [Max] 150.8 °F
Temperature Range [Min] -0.4 °F
Center Position P & B Blocked, A to T
Port Restrictor Plug Code None
Pilot Pressure Code E
AC/DC AC
Gauge Port SAE-4
Pilot/Drain Internal Drain
Actuator Type Solenoid
Mounting Subplate/Manifold Mount
Manual Override Plain Override
Valve Type Standard-Duty
Electrical Options None
Spool Code 3
Model No. DG5V-10-S-3C-E-T-M-FW-B-10
Actuation Identification Solenoid A, Solenoid B
Electrical Options Code None
Leakage Standard Performance
Pressure [Max] 5000 psi
Reducer Module Code None
Housing Code W
EN Code None
Crossover All Ports Blocked, or P & B Blocked, A to T
Electrical Connection No Connector
Port T Pressure Rating 3000 psi
Assembly Code None
Pressure Port Check Valve Code None
Coil Rating Code B
Gauge Ports Code None
NFPA Size D10
Electrical Connector Code None
Tank Port Rating 3000
Function 3-Position Spring Centered
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Pressure N/A
Pilot Valve Type Code S
Coil Type 1/2 in NPT Thread Wiring Housing
No. of Stages Two Stage
Pilot Drain Code T
Solenoid Energization Code None
Indicator Lights No
Fluid Cleanliness 19/17/14 micron
Surge Suppressor/Damper None
Solenoid Double
Mechanical Options None
Spool Spring Arrangement Code C
Solenoid Indicator Lights Code None
Compatible Fluids Petroleum Oil
Pilot Pressure [Max] 3000 psi
Surge Suppressor/Damper Code None
Operation Solenoid Operated
Manual Override Option Code None
Seal Material Buna-N
Response Type Code None
Reducer Module N/A
Response Type Standard Response
Spool Control Modification Code None
Pilot Valve Type CETOP 3, Standard Performance
Design No. 10
Overrides Plain Override Solenoid Ends
Rated Flow [Max] 175 gal/min
Body Material Ductile Iron
Weight 100.0 LB