Vickers D10 Solenoid Valve
Item #102086115
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-321801
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Compatible Fluids Petroleum Oil
Response Type Standard Response
Pilot Pressure Code E
Pilot Drain Code T
Housing Code W
Body Material Ductile Iron
Leakage Standard Performance
Indicator Lights No
Tank Port Rating 3000
Mounting Subplate/Manifold Mount
Assembly Code None
Rated Flow [Max] 175 gal/min
Port Restrictor Plug Code None
Gauge Port SAE-4
Electrical Connector Code None
Gauge Ports Code None
Overrides Plain Override Solenoid Ends
Solenoid Indicator Lights Code None
Port Restrictor Plugs None
Pilot Valve Type CETOP 3, Standard Performance
Fluid Cleanliness 19/17/14 micron
Function 3-Position Spring Centered
Spool Spring Arrangement Code C
Reducer Module Code None
Surge Suppressor/Damper Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Rating Code B
Valve Type Standard-Duty
Model No. DG5V-10-S-3C-E-T-M-FW-B-10
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 150.8 °F
Electrical Options None
Reducer Module N/A
Manual Override Option Code None
Spool Control Modification Code None
Seal Material Buna-N
Crossover All Ports Blocked, or P & B Blocked, A to T
Electrical Options Code None
Pressure [Max] 5000 psi
Pressure Port Check Valve Pressure N/A
Pilot Pressure [Max] 3000 psi
Mechanical Options None
Operation Solenoid Operated
Surge Suppressor/Damper None
Manual Override Plain Override
Response Type Code None
Solenoid Energization Code None
Pilot Valve Type Code S
Center Position P & B Blocked, A to T
Coil Type 1/2 in NPT Thread Wiring Housing
EN Code None
Solenoid Double
Electrical Connection No Connector
No. of Stages Two Stage
Port T Pressure Rating 3000 psi
Design No. 10
Pressure Port Check Valve Code None
Temperature Range [Min] -0.4 °F
Coil Type Code F
Pilot/Drain Internal Drain
Actuator Type Solenoid
NFPA Size D10
Spool Code 3
AC/DC AC
Weight 100.0 LB