- D05 Double Solenoid Operated Valve
- 115 VAC - 60 Hz
- Ground Terminal
- No Coil
- 3-Position Detented
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Response Type | Standard Response |
Port T Pressure Rating | 1000 psi |
Solenoid Air Gap Code | None |
Pilot Valve Type | N/A |
Function | 3-Position Detented |
Operation | Solenoid Operated |
Mechanical Options | None |
Center Position | All Ports Blocked |
Indicator Lights | Yes |
AC/DC | AC |
Port Restrictor Plugs | None |
Cycle Rate [Max] | N/A |
Spool Spring Arrangement Code | N |
Seal Material | Buna-N |
Coil Type | No Coil |
Overrides | No Overrides |
Flow Direction Code | 4 |
Solenoid | Double |
Surge Suppressor/Damper | None |
Mechanical Options Code | None |
Pilot/Drain | None |
Voltage & Frequency | 115 VAC – 60 Hz |
Rated Flow [Max] | 20 gal/min |
Reducer Module | N/A |
Design No. | 51 |
Pressure [Max] | 3000 psi |
Electrical Options Code | L |
Electrical Options | None |
NFPA Size | D05 |
Valve Type | Standard-Duty |
Spool Code | 2 |
Pressure Port Check Valve Pressure | N/A |
Crossover | All Ports Blocked |
Coil Rating Code | None |
Electrical Connection | Ground Terminal |
Actuator Type | Solenoid |
Weight | 10.0 LB |