Vickers02-339826

02-339826

Vickers D08 Solenoid Valve
Item #101920872
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-339826
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Indicator Lights Yes
Electrical Options Code None
Seal Material Buna-N
Coil Type Code F
Manual Override Option Code None
Design No. 10
Spool Spring Arrangement Code C
Actuator Type Solenoid
Electrical Options None
Center Position P to T, A & B Blocked
Spool Control Modification Code None
Function 3-Position Spring Centered
Response Type Standard Response
Leakage Standard Performance
Spool Indicator Switch Code None
No. of Stages Two Stage
Response Type Code None
Pilot Valve Type CETOP 3, Standard Performance
Port Restrictor Plug Code None
Electrical Connector Code T
Compatible Fluids Petroleum Oil
Operation Pilot Operated
Pressure [Max] 5000 psi
Overrides Plain Override Solenoid Ends
Spool Code 8
Fluid Cleanliness 19/17/14 micron
Surge Suppressor/Damper Code None
Pilot Pressure Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Body Material Gray Iron
Reducer Module Code None
Tank Port Rating 5000
Pilot Valve Type Code S
Performance Standard Performance
AC/DC AC
Gauge Ports Code None
Electrical Connection Wired Terminal Block
Model No. DG5V-8-S-8C-VM-FTWL-B-10
Rated Flow [Max] 175 gal/min
Port T Pressure Rating 5000 psi
Mechanical Options None
Pressure Port Check Valve Code None
Pressure Port Check Valve Pressure N/A
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot/Drain External Pilot/Internal Drain
Reducer Module No
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Coil Rating Code B
Solenoid Energization Code V
Crossover All Ports Open, Restricted
Surge Suppressor/Damper None
EN Code None
Manual Override Plain Override
Mechanical Options Code None
Solenoid Indicator Lights Code L
Pilot Drain Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Housing Code W
Port Restrictor Plugs None
Valve Type Standard-Duty
Solenoid Double
NFPA Size D08
Gauge Port SAE-4
Weight 35.0 LB