- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Operation | Pilot Operated |
Manual Override | Plain Override |
Solenoid Indicator Lights Code | L |
Pilot Drain Code | None |
No. of Stages | Two Stage |
Response Type Code | None |
Design No. | 10 |
AC/DC | AC |
Electrical Connection | Wired Terminal Block |
Seal Material | Buna-N |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Compatible Fluids | Petroleum Oil |
Port T Pressure Rating | 5000 psi |
Spool Indicator Switch Code | None |
Overrides | Plain Override Solenoid Ends |
Port Restrictor Plug Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Gauge Port | SAE-4 |
Spool Spring Arrangement Code | C |
Leakage | Standard Performance |
Electrical Options | None |
NFPA Size | D08 |
Valve Type | Standard-Duty |
Electrical Options Code | None |
Indicator Lights | Yes |
Manual Override Option Code | None |
Body Material | Gray Iron |
Actuator Type | Solenoid |
Model No. | DG5V-8-S-8C-VM-FTWL-B-10 |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Pilot Valve Type Code | S |
Response Type | Standard Response |
Pressure Port Check Valve Code | None |
Mounting | Subplate/Manifold Mount |
Pilot Pressure Code | None |
EN Code | None |
Coil Type Code | F |
Center Position | P to T, A & B Blocked |
Gauge Ports Code | None |
Function | 3-Position Spring Centered |
Pilot/Drain | External Pilot/Internal Drain |
Mechanical Options | None |
Fluid Cleanliness | 19/17/14 micron |
Pressure Port Check Valve Pressure | N/A |
Mechanical Options Code | None |
Pressure [Max] | 5000 psi |
Solenoid | Double |
Surge Suppressor/Damper | None |
Tank Port Rating | 5000 |
Crossover | All Ports Open, Restricted |
Electrical Connector Code | T |
Solenoid Energization Code | V |
Spool Control Modification Code | None |
Pilot Valve Type | CETOP 3, Standard Performance |
Reducer Module | No |
Rated Flow [Max] | 175 gal/min |
Spool Code | 8 |
Performance | Standard Performance |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Coil Rating Code | B |
Housing Code | W |
Reducer Module Code | None |
Surge Suppressor/Damper Code | None |
Port Restrictor Plugs | None |
Weight | 35.0 LB |