Vickers D08 Solenoid Valve
Item #101979716
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-329117
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Select an Auto-Replenish Interval
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Crossover All Ports Blocked
Coil Type Code F
Electrical Options Code None
Solenoid Indicator Lights Code None
Port T Pressure Rating 5000 psi
Manual Override Option Code None
Pilot/Drain External Pilot/Internal Drain
Indicator Lights No
Port Restrictor Plugs None
Mechanical Options Code None
EN Code None
Coil Rating Code B
Pilot Drain Code None
Pressure Port Check Valve Pressure N/A
Performance High Performance
NFPA Size D08
Spool Code 2
Operation Pilot Operated
Reducer Module No
Model No. DG5V-8-H-2C-M-FW-B-10
Pilot Valve Type Code H
Pressure [Max] 5000 psi
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Spring Arrangement Code C
Response Type Code None
Electrical Options None
Center Position All Ports Blocked
Tank Port Rating 5000
Response Type Standard Response
Leakage Standard Performance
Electrical Connection No Connector
Function 3-Position Spring Centered
Valve Type Standard-Duty
Overrides Plain Override Solenoid Ends
Housing Code W
Seal Material Buna-N
Surge Suppressor/Damper Code None
Rated Flow [Max] 175 gal/min
Pilot Valve Type CETOP 3, High Performance
AC/DC AC
Pilot Pressure Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Gauge Ports Code None
Fluid Cleanliness 19/17/14 micron
Reducer Module Code None
Surge Suppressor/Damper None
Actuator Type Solenoid
Body Material Gray Iron
Spool Indicator Switch Code None
Pressure Port Check Valve Code None
Electrical Connector Code None
Gauge Port SAE-4
Port Restrictor Plug Code None
Manual Override Plain Override
Spool Center Condition A Port and Double Offset sensing switch on B Port
No. of Stages Two Stage
Design No. 10
Spool Control Modification Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options None
Solenoid Double
Mounting Subplate/Manifold Mount
Weight 35.0 LB