- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
Body Material | Gray Iron |
Mechanical Options Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Manual Override | Plain Override |
Spool Code | 2 |
Performance | High Performance |
Pressure Port Check Valve Code | None |
Operation | Pilot Operated |
Function | 3-Position Spring Centered |
Fluid Cleanliness | 19/17/14 micron |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Electrical Options | None |
Center Position | All Ports Blocked |
Pilot Valve Type Code | H |
Rated Flow [Max] | 175 gal/min |
Coil Type Code | F |
Housing Code | W |
Manual Override Option Code | None |
Spool Control Modification Code | None |
Port Restrictor Plugs | None |
Pilot Drain Code | None |
Pilot Pressure Code | None |
Overrides | Plain Override Solenoid Ends |
Electrical Connection | No Connector |
Pressure Port Check Valve Pressure | N/A |
Seal Material | Buna-N |
EN Code | None |
Port Restrictor Plug Code | None |
Spool Indicator Switch Code | None |
Pilot/Drain | External Pilot/Internal Drain |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Reducer Module Code | None |
Coil Rating Code | B |
Model No. | DG5V-8-H-2C-M-FW-B-10 |
Tank Port Rating | 5000 |
Solenoid | Double |
Mechanical Options | None |
Design No. | 10 |
Valve Type | Standard-Duty |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Electrical Connector Code | None |
Port T Pressure Rating | 5000 psi |
Pressure [Max] | 5000 psi |
Indicator Lights | No |
Electrical Options Code | None |
AC/DC | AC |
No. of Stages | Two Stage |
Mounting | Subplate/Manifold Mount |
Gauge Port | SAE-4 |
Solenoid Indicator Lights Code | None |
Actuator Type | Solenoid |
Leakage | Standard Performance |
Response Type Code | None |
Pilot Valve Type | CETOP 3, High Performance |
Response Type | Standard Response |
NFPA Size | D08 |
Spool Spring Arrangement Code | C |
Surge Suppressor/Damper Code | None |
Compatible Fluids | Petroleum Oil |
Solenoid Energization Code | None |
Crossover | All Ports Blocked |
Surge Suppressor/Damper | None |
Reducer Module | No |
Gauge Ports Code | None |
Weight | 35.0 LB |