- Solenoid Actuated Valve
- Solenoid Operated Operation
- D05 NFPA Size
- Single Solenoid
- 2-Position Spring Centered, End To Center Function
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Seal Material | Buna-N |
Model No. | DG4S4L-012B-B-60 |
Valve Type | Standard-Duty |
Actuation Identification | Solenoid B |
Flow Direction Code | 4 |
Response Time | 20 to 40 ms |
Pressure [Max] | 4500 psi |
Leakage | Standard Performance |
Pressure Port Check Valve Pressure | N/A |
Compatible Fluids | Petroleum Oil |
Overrides | No Overrides |
Reducer Module | N/A |
Cycle Rate [Max] | N/A |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Spool Spring Arrangement Code | B |
Coil Type Code | None |
Mechanical Options Code | None |
Operation | Solenoid Operated |
Electrical Connection | Lead Wires w/o Terminal Box |
Rated Flow [Max] | 24 gal/min |
Performance | Standard Performance |
Actuator Type | Solenoid |
Fluid Cleanliness | 19/17/14 micron |
Coil Rating Code | B |
Spool Code | 2 |
Function | 2-Position Spring Centered, End To Center |
Tank Port Rating | 1000 |
NFPA Size | D05 |
Electrical Options | None |
Design No. | 60 |
Surge Suppressor/Damper | None |
Pilot Valve Type | N/A |
Solenoid | Single |
Mounting | Subplate/Manifold Mount |
Electrical Options Code | L |
AC/DC | AC |
Port Restrictor Plugs | None |
No. of Stages | Single Stage |
Mechanical Options | None |
Temperature Range [Min] | 68 °F |
Center Position | All Ports Blocked |
Body Material | Gray Iron |
Manual Override | Plain Override |
Pilot/Drain | None |
Port T Pressure Rating | 1000 psi |
Indicator Lights | Yes |
Response Type | Standard Response |
Temperature Range [Max] | 122 °F |
Crossover | All Ports Blocked |
Coil Type | Flying Leads |
Weight | 10.0 LB |