- Solenoid Actuated Valve
- Solenoid Operated Operation
- D05 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Pressure Port Check Valve Pressure | N/A |
| Flow Direction Code | 4 |
| Pilot/Drain | None |
| Tank Port Rating | 1000 |
| Cycle Rate [Max] | N/A |
| Crossover | All Ports Blocked |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Solenoid | Single |
| Port T Pressure Rating | 1000 psi |
| AC/DC | AC |
| Reducer Module | N/A |
| Mechanical Options Code | None |
| Electrical Options Code | None |
| Indicator Lights | No |
| Electrical Connection | DIN 43650 |
| Design No. | 60 |
| Model No. | DG4S4-012A-U-C-60 |
| NFPA Size | D05 |
| Overrides | No Overrides |
| Port Restrictor Plugs | None |
| Coil Type Code | U |
| Rated Flow [Max] | 25 gal/min |
| Pressure [Max] | 3600 psi |
| Pilot Valve Type | N/A |
| Response Type | Standard Response |
| Spool Code | 2 |
| Operation | Solenoid Operated |
| Coil Rating Code | C |
| Spool Spring Arrangement Code | A |
| Center Position | All Ports Blocked |
| Seal Material | Buna-N |
| Electrical Options | None |
| Surge Suppressor/Damper | None |
| Valve Type | Standard-Duty |
| Function | 2-Position Spring Offset |
| Actuator Type | Solenoid |
| Mechanical Options | None |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Weight | 10.0 LB |