These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.
features
Efficient control of greater hydraulic powers without increasing solenoid power consumption
Multi-fluid capability without the need to change seals
Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
Up to 21 gpm at 5,000 psi
Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Surge Suppressor/Damper Code
None
Pilot Valve Type
N/A
Electrical Options
None
Crossover
All Ports Open, Restricted
Coil Type
Dual 6.3 mm Spade
Rated Flow [Max]
21 gal/min
EN Code
None
Center Position
P to T, A & B Blocked
Pilot/Drain
None
Solenoid
Double
Function
3-Position Spring Centered
Valve Type
High-Performance
Electrical Connection
No Connector
Coil Rating Code
G
Solenoid Code
G
Function Code
8
Housing Code
None
Mechanical Options
None
Surge Suppressor/Damper
None
Port Restrictor Plugs
None
Pressure Port Check Valve Pressure
N/A
Operation
Solenoid Operated
Spool Code
8
Spool Indicator Switch Code
None
Cycle Rate [Max]
N/A
Solenoid Indicator Lights Code
None
Port T Code
7
Overrides
No Overrides
Reducer Module
N/A
Solenoid Energization Code
V
Design No.
61
Coil Type Code
SP2
Actuator Type
Solenoid
NFPA Size
D03
Electrical Connector Code
None
AC/DC
DC
Indicator Lights
No
Spool Shift Timing
N/A
Spool Spring Arrangement Code
C
Pressure [Max]
5075 psi
Voltage & Frequency
12 VDC
Seal Material
Buna-N
Response Type
Standard Response
Port T Pressure Rating
3000 psi
Manual Override Option Code
None
Port Restrictor Plug Code
None
Weight
5.0 LB
We're here for you