Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Poles
4
RPM
1800 rpm
Motor Shaft Length
4 5/8 in
Voltage
230/460
Mounting Style
F-1
Rotation
R
Motor Application
General Purpose
Epact Nominal Full Load Efficiency
92.4 %
Full Load Pf
85
Open End Bearing
6309
Full Load rpm
1770 rpm
Voltage Rating
460, 230
VoltCode
E1
Brake Feature
No
Mult. Sym.
L1
Enclosure
OPSB
Substitute Motor
M2535T
Phase
Three Phase
Motor Shaft Size
1 7/8 in
C Face Kit
40-1400
Full Load Amps
35
RefPicture
EMDP
Full Load Efficiency
94.1 %
Drive End Bearing
6311
Mounting
Rigid Base
Frame Material
Steel
Washdown Duty
No
Frame
286T
Type
4052M
C Dimension
25.06 in
BALD Family Names
Premium Efficient, Nema Premium™
Service Factor
1.15
Enclosure Designation
OPSB - Open Slotted Band
Product Line
RG
Hz
60 Hz
Design
B
Frame Size
Shaft Input, Not a C-Face
Useable at 208V
Yes
Efficiency Group
Premium Efficient
Weight
372.0 LB
EAN or UPC
781568105054
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back