Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Useable at 208V
Yes
Mult. Sym.
L1
Voltage Rating
460, 230
Full Load Efficiency
94.1 %
C Face Kit
40-1400
Rotation
R
Brake Feature
No
Motor Shaft Size
1 7/8 in
Phase
Three Phase
Full Load Pf
85
Frame
286T
BALD Family Names
Premium Efficient, Nema Premium™
Washdown Duty
No
Open End Bearing
6309
Epact Nominal Full Load Efficiency
92.4 %
RefPicture
EMDP
Type
4052M
VoltCode
E1
Mounting Style
F-1
Enclosure Designation
OPSB - Open Slotted Band
Substitute Motor
M2535T
Efficiency Group
Premium Efficient
Product Line
RG
Full Load Amps
35
Mounting
Rigid Base
Drive End Bearing
6311
C Dimension
25.06 in
Design
B
Hz
60 Hz
Voltage
230/460
Frame Size
Shaft Input, Not a C-Face
RPM
1800 rpm
Motor Application
General Purpose
Service Factor
1.15
Enclosure
OPSB
Poles
4
Motor Shaft Length
4 5/8 in
Frame Material
Steel
Full Load rpm
1770 rpm
Weight
372.0 LB
EAN or UPC
781568105054
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back