870160

Vickers D03 Solenoid Valve
Item #101872658
  • D03 Direct Operated Double Solenoid Valve
  • 110/120V 50/60 HZ
  • 3 Position, Spring Centered
  • Terminal Box
  • 10.6 gal/min
  • w/o Indicator Lights
  • Center Position: P Blocked, A & B to T
  • Crossover: P Blocked, A or B to T
  • 5075 psi
+ Show More + Show Less
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • D03 Direct Operated Double Solenoid Valve
  • 110/120V 50/60 HZ
  • 3 Position, Spring Centered
  • Terminal Box
  • 10.6 gal/min

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Overrides No Overrides
Reducer Module N/A
EN Code None
Coil Type Flying Leads, 1/2 NPT Thread Wiring Housing
Pilot/Drain None
Solenoid Code B
Solenoid Energization Code None
Spool Indicator Switch Code None
Mechanical Options None
Spool Code 6
Port T Code 6
Spool Shift Timing N/A
Solenoid Double
Electrical Connection Terminal Box
Electrical Connector Code None
NFPA Size D03
Valve Type High-Performance
Manufacturer Part No. DG4V 3 6C M FW B6 60
Pressure Port Check Valve Pressure N/A
Manual Override Option Code None
Mounting Manifold Mount
Center Position P Blocked, A & B to T
Housing Code W
Solenoid Indicator Lights Code None
Seal Material Buna-N
Electrical Options None
Indicator Lights No
Pressure [Max] 5,075 psi
Surge Suppressor/Damper Code None
Operation Solenoid Operated
Crossover P Blocked, A or B to T
Rated Flow [Max] 21.00 gal/min
Spool Spring Arrangement Code C
Port Restrictor Plugs None
Pilot Valve Type N/A
Function Code 6
Port T Pressure Rating 3000 psi
Rated Flow 21.00 gal/min
Coil Type Code F
Actuator Type Solenoid
Port Restrictor Plug Code None
Model No. DG4V 3 6C M FW B6 60
Cycle Rate [Max] 0
Coil Rating Code B
Design No. 60
AC/DC AC
Surge Suppressor/Damper None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Standard Response
Function 3-Position, 4-Way, Spring Centered
Weight 5.0 LB