Skip to content Skip to navigation menu
Vickers by Danfoss836AN00676A

836AN00676A

Vickers D08 Solenoid Valve
Item #112079690
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Vickers by Danfoss836AN00676A
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Actuator Type Solenoid
Performance Standard Performance
Operation Pilot Operated
Compatible Fluids Petroleum Oil
Rated Flow [Max] 175 gal/min
NFPA Size D08
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
AC/DC AC
Pressure [Max] 5000 psi
Mounting Subplate/Manifold Mount
Manual Override Plain Override
Function Spring Centered
Leakage Standard Performance
Pilot/Drain Internal Pilot/External Drain
Spool Spring Arrangement Code C
Temperature Range [Min] -40 °F
No. of Stages Two Stage
Model No. DG5V-8-S-6C-K-M-FW-B-10
Temperature Range [Max] 230 °F
Seal Material Buna-N
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Body Material Ductile Iron
Reducer Module No
Actuation Identification Solenoid A, Solenoid B
Weight 36.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison