Vickers by Danfoss02-363417

02-363417

DG5V-10 Series Pilot Operated Directional Valve
Item #101907780
  • Double Sol Pilot Op Dir Valve
  • 3-Pos Spring Ctr
  • 110/120 VAC - 50/60 Hz
  • Flying Leads, 1/2 NPT Thread Wiring Hsg
  • No Connector
  • Ctr Pos: P to A & B, T Blocked
  • Ext Pilot / Int Drain
  • Adj Pilot Chokes on Both Ends
  • Pilot Valve: CETOP 3, Std Performance
+ Show More + Show Less
Vickers by Danfoss02-363417
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Double Sol Pilot Op Dir Valve
  • 3-Pos Spring Ctr
  • 110/120 VAC - 50/60 Hz
  • Flying Leads, 1/2 NPT Thread Wiring Hsg
  • No Connector

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Reducer Module Code None
Response Type Standard Response
Pilot Drain Code T
Reducer Module N/A
Spool Code 7
Solenoid Double
Coil Type Code F
EN Code None
Indicator Lights Yes
Port T Pressure Rating 3000 psi
Pilot Valve Type CETOP 3, Standard Performance
Response Type Code None
Electrical Connection No Connector
Pilot/Drain External Pilot/Internal Drain
Pressure Port Check Valve Code None
Gauge Port SAE-4
Gauge Ports Code None
Design No. 10
Pilot Pressure Code E
Actuator Type Solenoid
Solenoid Indicator Lights Code L
Function 3-Position Spring Centered
Electrical Options None
Voltage & Frequency 110/120 VAC – 50/60 Hz
Manual Override Option Code None
Solenoid Energization Code V
Spool Spring Arrangement Code C
Pilot Pressure [Max] 3000 psi
Port Restrictor Plug Code None
AC/DC AC
Center Position P to A & B, T Blocked
Coil Rating Code B
Port Restrictor Plugs None
NFPA Size D10
Coil Type Flying Leads, 1/2 NPT Thread Wiring Housing
Pressure Port Check Valve Pressure N/A
Mechanical Options Adjust Pilot Chokes on Both Ends
Overrides Plain Override Solenoid Ends
Valve Type Standard-Duty
Electrical Options Code None
Crossover P to A or B, T & A or B Blocked
Pressure [Max] 5000 psi
Electrical Connector Code None
Spool Control Modification Code 2
Surge Suppressor/Damper None
Operation Pilot Operated
Assembly Code None
Housing Code W
Rated Flow [Max] 290 gal/min
Surge Suppressor/Damper Code None
Seal Material Buna-N
Pilot Valve Type Code S
Weight 100.0 LB