Vickers by Danfoss02-363089

02-363089

DG5V-10 Series Pilot Operated Directional Valve
Item #101905796
  • Single Solenoid Pilot Operated Directional Valve
  • 2-Position Spring Offset
  • 115 VAC - 50/60 Hz
  • No Coil
  • No Connector
  • Ctr Pos: All Ports Open Over Tapers
  • Internal Pilot / External Drain
  • None
  • Pilot Valve: CETOP 5, Air Gap
+ Show More + Show Less
Vickers by Danfoss02-363089
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Single Solenoid Pilot Operated Directional Valve
  • 2-Position Spring Offset
  • 115 VAC - 50/60 Hz
  • No Coil
  • No Connector

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Response Type Code None
Pressure Port Check Valve Pressure 5 psi
Port Restrictor Plug Code None
Pressure Port Check Valve Code K
Manual Override Option Code None
Valve Type Standard-Duty
Solenoid Indicator Lights Code None
Pilot/Drain Internal Pilot/External Drain
Pilot Drain Code None
Reducer Module N/A
Housing Code None
Spool Control Modification Code None
Spool Spring Arrangement Code A
Solenoid Single
Mechanical Options None
Coil Type Code None
Design No. 10
Reducer Module Code None
Surge Suppressor/Damper None
Indicator Lights No
Seal Material Buna-N
EN Code None
Port T Pressure Rating 3000 psi
Port Restrictor Plugs None
Surge Suppressor/Damper Code None
Rated Flow [Max] 290 gal/min
Electrical Options None
Electrical Connector Code None
Actuator Type Solenoid
Electrical Options Code None
Pilot Pressure Code None
NFPA Size D10
Gauge Ports Code None
Solenoid Energization Code None
Pilot Valve Type Code A
Coil Type No Coil
Coil Rating Code B
Pilot Pressure [Max] 3000 psi
Voltage & Frequency 115 VAC – 50/60 Hz
Pressure [Max] 5000 psi
Function 2-Position Spring Offset
Pilot Valve Type CETOP 5, Air Gap
Center Position All Ports Open Over Tapers
AC/DC AC
Electrical Connection No Connector
Gauge Port SAE-4
Response Type Standard Response
Overrides None
Crossover All Ports Open
Spool Code 9
Operation Pilot Operated
Assembly Code None
Weight 100.0 LB