Vickers by Danfoss02-363070

02-363070

Vickers D08 Solenoid Valve
Item #101910592
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-363070
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
NFPA Size D08
Temperature Range [Max] 230 °F
Fluid Cleanliness 19/17/14 micron
Gauge Port SAE-4
Manual Override Option Code None
Leakage High Performance
Center Position P to T, A & B Blocked
Overrides Plain Override Solenoid Ends
Coil Rating Code B
Solenoid Double
Electrical Options None
Manual Override Plain Override
Response Type Standard Response
Pilot Drain Code None
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Model No. DG5V-8-H-8C-2-E-VM-FW-B-10
Housing Code W
Compatible Fluids Petroleum Oil
Coil Type Code F
Electrical Connector Code None
Pressure Port Check Valve Pressure N/A
Function 3-Position Spring Centered
Actuator Type Solenoid
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Tank Port Rating 5000
Port Restrictor Plug Code None
Solenoid Indicator Lights Code None
Electrical Connection No Connector
Mechanical Options Adjust Pilot Chokes on Both Ends
Pilot Valve Type CETOP 3, High Performance
Seal Material Buna-N
Electrical Options Code None
Pilot Valve Type Code H
Rated Flow [Max] 175 gal/min
Surge Suppressor/Damper None
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Code 8
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
No. of Stages Two Stage
Reducer Module Code None
Solenoid Energization Code V
AC/DC AC
Actuation Identification Solenoid A, Solenoid B
Pressure [Max] 5000 psi
Operation Pilot Operated
Port Restrictor Plugs None
Valve Type Standard-Duty
Spool Control Modification Code 2
Mechanical Options Code None
EN Code None
Pilot/Drain External Pilot/External Drain
Pressure Port Check Valve Code None
Performance High Performance
Spool Spring Arrangement Code C
Body Material Ductile Iron
Gauge Ports Code None
Temperature Range [Min] -40 °F
Port T Pressure Rating 5000 psi
Crossover All Ports Open, Restricted
Pilot Pressure Code E
Mounting Subplate/Manifold Mount
Response Type Code None
Indicator Lights No
Reducer Module No
Weight 35.0 LB