- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
NFPA Size | D08 |
Mechanical Options | None |
Response Type Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Solenoid Energization Code | None |
Pressure [Max] | 5000 psi |
Rated Flow [Max] | 175 gal/min |
Overrides | Plain Override Solenoid Ends |
Leakage | High Performance |
Function | 3-Position Spring Centered |
Gauge Ports Code | None |
Mounting | Subplate/Manifold Mount |
Spool Control Modification Code | None |
Response Type | Standard Response |
Indicator Lights | No |
Model No. | DG5V-8-H-33C-T-M-FW-B-10 |
Pilot Valve Type Code | H |
Coil Type Code | F |
Solenoid | Double |
Crossover | P Blocked, A or B to T |
Body Material | Ductile Iron |
Port Restrictor Plugs | None |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Solenoid Indicator Lights Code | None |
Pressure Port Check Valve Pressure | N/A |
Compatible Fluids | Petroleum Oil |
Pressure Port Check Valve Code | None |
Manual Override | Plain Override |
Spool Spring Arrangement Code | C |
Spool Code | 33 |
Seal Material | Buna-N |
No. of Stages | Two Stage |
Pilot Valve Type | CETOP 3, High Performance |
Pilot Drain Code | T |
Manual Override Option Code | None |
Housing Code | W |
Gauge Port | SAE-4 |
Design No. | 10 |
Temperature Range [Max] | 230 °F |
Valve Type | Standard-Duty |
Performance | High Performance |
Operation | Pilot Operated |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Port Restrictor Plug Code | None |
Pilot Pressure Code | None |
Actuation Identification | Solenoid A, Solenoid B |
Center Position | P Blocked, A & B to T |
Temperature Range [Min] | -40 °F |
Fluid Cleanliness | 19/17/14 micron |
Electrical Connector Code | None |
Actuator Type | Solenoid |
Surge Suppressor/Damper | None |
Spool Indicator Switch Code | None |
Reducer Module | No |
Coil Rating Code | B |
Surge Suppressor/Damper Code | None |
Pilot/Drain | Internal Pilot/Internal Drain |
Mechanical Options Code | None |
Electrical Options | None |
Electrical Options Code | None |
Port T Pressure Rating | 5000 psi |
EN Code | None |
Tank Port Rating | 5000 |
AC/DC | AC |
Electrical Connection | No Connector |
Reducer Module Code | None |
Weight | 35.0 LB |