Vickers by Danfoss02-360351

02-360351

Vickers D08 Solenoid Valve
Item #101907000
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-360351
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.

compliances

  • 0

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Design No. 10
Coil Type Code F
Indicator Lights No
Electrical Connection No Connector
Seal Material Buna-N
Pilot Valve Type CETOP 3, High Performance
Port Restrictor Plugs None
Center Position All Ports Blocked
AC/DC AC
Valve Type Standard-Duty
Actuator Type Solenoid
Compatible Fluids Petroleum Oil
Rated Flow [Max] 175 gal/min
Spool Indicator Switch Code None
Reducer Module Code None
Mechanical Options None
Solenoid Energization Code None
Mounting Subplate/Manifold Mount
Spool Spring Arrangement Code A
Mechanical Options Code None
Spool Control Modification Code None
Housing Code W
Performance High Performance
No. of Stages Two Stage
Pressure Port Check Valve Code None
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5000 psi
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper Code None
Temperature Range [Min] -40 °F
Model No. DG5V-8-H-2A-T-M-FW-B-10
Coil Rating Code B
Solenoid Single
Surge Suppressor/Damper None
NFPA Size D08
Voltage & Frequency 110/120 VAC - 50/60 Hz
Reducer Module No
Response Type Standard Response
Electrical Connector Code None
Gauge Ports Code None
Pilot Valve Type Code H
Solenoid Indicator Lights Code None
Crossover All Ports Blocked
Operation Pilot Operated
EN Code None
Port Restrictor Plug Code None
Spool Code 2
Electrical Options None
Tank Port Rating 5000
Pilot Pressure Code None
Pilot/Drain External Pilot/Internal Drain
Function 2-Position Spring Offset
Temperature Range [Max] 230 °F
Spool Center Condition B Port End
Actuation Identification Solenoid B
Manual Override Plain Override
Pilot Drain Code T
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Leakage High Performance
Response Type Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Manual Override Option Code None
Fluid Cleanliness 19/17/14 micron
Electrical Options Code None
Body Material Ductile Iron
Gauge Port SAE-4
Port T Pressure Rating 5000 psi
Weight 35.0 LB