Vickers D08 Solenoid Valve
Item #101908005
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-360276
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Center Position All Ports Open
Indicator Lights No
Spool Indicator Switch Code None
Overrides Plain Override Solenoid Ends
Electrical Connection No Connector
Spool Spring Arrangement Code A
Response Type Standard Response
Tank Port Rating 5000
Pilot Valve Type CETOP 3, Standard Performance
Pressure [Max] 5000 psi
Model No. DG5V-8-S-0A-E-M-U-B-10
Housing Code None
Electrical Options Code None
Solenoid Single
Electrical Options None
Coil Type Code U
Valve Type Standard-Duty
Mechanical Options None
Pilot Drain Code None
Solenoid Energization Code None
Pilot Valve Type Code S
Pressure Port Check Valve Code None
Manual Override Plain Override
Port Restrictor Plug Code None
Rated Flow [Max] 185 gal/min
Mechanical Options Code None
Gauge Port SAE-4
Coil Type DIN 43650
Design No. 10
Electrical Connector Code None
Surge Suppressor/Damper None
Gauge Ports Code None
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code None
Crossover All Ports Open
AC/DC AC
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Response Type Code None
Pilot Pressure Code E
Port T Pressure Rating 5000 psi
Port Restrictor Plugs None
Surge Suppressor/Damper Code None
Coil Rating Code B
Reducer Module N/A
Function 2-Position Spring Offset
NFPA Size D08
Pilot/Drain External Pilot/Internal Drain
EN Code None
Spool Code 0
Manual Override Option Code None
Operation Pilot Operated
Seal Material Buna-N
Reducer Module Code None
Weight 35.0 LB