- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Spool Indicator Switch Code | None |
| Reducer Module | No |
| Reducer Module Code | None |
| Mechanical Options | None |
| Electrical Options | None |
| Electrical Connection | Wired Terminal Block |
| Manual Override Option Code | None |
| Pressure Port Check Valve Code | K |
| Surge Suppressor/Damper Code | None |
| NFPA Size | D08 |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Coil Rating Code | B |
| Actuation Identification | Solenoid A, Solenoid B |
| Gauge Ports Code | None |
| Design No. | 10 |
| Pilot Valve Type Code | S |
| No. of Stages | Two Stage |
| Overrides | Plain Override Solenoid Ends |
| Rated Flow [Max] | 175 gal/min |
| Spool Control Modification Code | None |
| Indicator Lights | Yes |
| Coil Type Code | F |
| Temperature Range [Max] | 230 °F |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Surge Suppressor/Damper | None |
| Pressure [Max] | 5000 psi |
| Mechanical Options Code | None |
| Operation | Pilot Operated |
| Housing Code | W |
| Tank Port Rating | 5000 |
| Manual Override | Plain Override |
| Valve Type | Standard-Duty |
| Compatible Fluids | Petroleum Oil |
| Port T Pressure Rating | 5000 psi |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Solenoid Indicator Lights Code | L |
| Function | 3-Position Spring Centered |
| Fluid Cleanliness | 19/17/14 micron |
| Center Position | All Ports Blocked |
| Model No. | DG5V-8-S-2C-K-M-FTWL-B-10 |
| Electrical Connector Code | T |
| Solenoid Energization Code | None |
| Electrical Options Code | None |
| Pilot Drain Code | None |
| Temperature Range [Min] | -40 °F |
| AC/DC | AC |
| Spool Spring Arrangement Code | C |
| Actuator Type | Solenoid |
| Leakage | Standard Performance |
| Pilot Pressure Code | None |
| Response Type | Standard Response |
| EN Code | None |
| Performance | Standard Performance |
| Body Material | Ductile Iron |
| Response Type Code | None |
| Mounting | Subplate/Manifold Mount |
| Seal Material | Buna-N |
| Crossover | All Ports Blocked |
| Spool Code | 2 |
| Solenoid | Double |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Pilot/Drain | Internal Pilot/External Drain |
| Gauge Port | SAE-4 |
| Pressure Port Check Valve Pressure | 5 psi |
| Port Restrictor Plug Code | None |
| Port Restrictor Plugs | None |
| Weight | 35.0 LB |