Vickers D10 Solenoid Valve
Item #101937083
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-355439
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Function 3-Position Spring Centered
Electrical Connector Code None
Electrical Options Code None
Gauge Port SAE-4
Pressure Port Check Valve Code None
Pressure Port Check Valve Pressure N/A
Pilot Valve Type CETOP 3, High Performance
Pilot Pressure [Max] 3000 psi
Center Position P to T, A & B Blocked
Actuator Type Solenoid
Pressure [Max] 5000 psi
Manual Override Option Code None
Housing Code None
Port Restrictor Plugs None
Gauge Ports Code None
Coil Type Code U
Spool Spring Arrangement Code C
Reducer Module Code None
Crossover All Ports Open, Restricted
Solenoid Energization Code V
Assembly Code None
NFPA Size D10
Electrical Options None
Surge Suppressor/Damper None
Coil Type DIN 43650
Design No. 10
Pilot Pressure Code E
Voltage & Frequency 110 VAC - 50 Hz
Valve Type Standard-Duty
Rated Flow [Max] 290 gal/min
Operation Pilot Operated
Model No. DG5V-10-H-8C-E-VM-U-A-10
Port T Pressure Rating 3000 psi
Overrides Plain Override Solenoid Ends
Indicator Lights No
Response Type Code None
Mechanical Options None
Spool Control Modification Code None
Surge Suppressor/Damper Code None
Seal Material Buna-N
Pilot Valve Type Code H
EN Code None
Reducer Module N/A
Pilot Drain Code None
Port Restrictor Plug Code None
AC/DC AC
Solenoid Indicator Lights Code None
Pilot/Drain External Pilot/Internal Drain
Coil Rating Code A
Spool Code 8
Manual Override Plain Override
Tank Port Rating 3000
Electrical Connection No Connector
Solenoid Double
Response Type Standard Response
Weight 100.0 LB