Vickers D03 Solenoid Valve

02-354319

Vickers D03 Solenoid Valve
Item #101914965
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Valve Type High-Performance
Port Restrictor Plug Code None
Pilot Valve Type N/A
Spool Code 6
Spool Shift Timing N/A
Function Code 6
Function 3-Position Detented
Pilot/Drain None
Operation Solenoid Operated
Seal Material Buna-N
Coil Type Code F
Manual Override Plain Override
Reducer Module No
EN Code None
Mechanical Options None
Housing Code W
Electrical Connection Instaplug Male & Female Receptacle
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 3000 psi
Spool Spring Arrangement Code N
Port T Code 6
No. of Stages Single Stage
Pressure Port Check Valve Pressure N/A
Temperature Range [Max] 158 °F
Response Time 15 to 23 ms
Tank Port Rating 3046
Actuator Type Solenoid
Model No. DG4V 3 6N M FPBWL B6 60
Solenoid Double
Electrical Connector Code PB
Temperature Range [Min] -4 °F
Center Position P Blocked, A & B to T
Indicator Lights Yes
Rated Flow [Max] 20 gal/min
Actuation Identification Solenoid A, Solenoid B
NFPA Size D03
Response Type Standard Response
Leakage Standard Performance
Solenoid Indicator Lights Code L
Performance High Performance
Surge Suppressor/Damper Code None
Compatible Fluids Petroleum Oil
Pressure [Max] 5000 psi
Solenoid Code B
Surge Suppressor/Damper None
Mounting Subplate/Manifold Mount
Electrical Options None
Coil Rating Code B
Port Restrictor Plugs None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Overrides No Overrides
Spool Indicator Switch Code None
AC/DC AC
Cycle Rate [Max] N/A
Body Material Gray Iron
Crossover P Blocked, A or B to T
Manual Override Option Code None
Fluid Cleanliness 19/17/14 micron
Design No. 60
Weight 5.0 LB