- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Solenoid | Double |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Fluid Cleanliness | 19/17/14 micron |
| Port Restrictor Plugs | None |
| Pilot Pressure Code | None |
| NFPA Size | D08 |
| Electrical Options Code | None |
| Pilot Drain Code | None |
| Electrical Connector Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Indicator Lights | No |
| Spool Code | 11 |
| Mounting | Subplate/Manifold Mount |
| EN Code | None |
| Pressure Port Check Valve Code | None |
| Manual Override Option Code | None |
| Spool Spring Arrangement Code | C |
| Pressure [Max] | 5000 psi |
| Coil Type Code | F |
| Surge Suppressor/Damper | None |
| Operation | Pilot Operated |
| Tank Port Rating | 5000 |
| Pilot Valve Type Code | H |
| Seal Material | Buna-N |
| Spool Indicator Switch Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Response Type Code | None |
| Body Material | Ductile Iron |
| No. of Stages | Two Stage |
| Actuator Type | Solenoid |
| Surge Suppressor/Damper Code | None |
| Design No. | 10 |
| Mechanical Options Code | None |
| Temperature Range [Max] | 230 °F |
| Reducer Module | No |
| Valve Type | Standard-Duty |
| Function | 3-Position Spring Centered |
| Pilot/Drain | Internal Pilot/External Drain |
| Solenoid Indicator Lights Code | None |
| Port Restrictor Plug Code | None |
| Gauge Port | SAE-4 |
| Electrical Connection | No Connector |
| Actuation Identification | Solenoid A, Solenoid B |
| Crossover | N/A |
| Leakage | High Performance |
| Mechanical Options | None |
| Overrides | Plain Override Solenoid Ends |
| Spool Control Modification Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Pilot Valve Type | CETOP 3, High Performance |
| Compatible Fluids | Petroleum Oil |
| Performance | High Performance |
| Port T Pressure Rating | 5000 psi |
| Temperature Range [Min] | -40 °F |
| AC/DC | AC |
| Response Type | Standard Response |
| Manual Override | Plain Override |
| Coil Rating Code | B |
| Rated Flow [Max] | 175 gal/min |
| Housing Code | W |
| Electrical Options | None |
| Gauge Ports Code | None |
| Model No. | DG5V-8-H-11C-M-FW-B-10 |
| Center Position | P & B to T, A Blocked |
| Solenoid Energization Code | None |
| Reducer Module Code | None |
| Weight | 35.0 LB |