Skip to content Skip to navigation menu
Vickers by Danfoss02-343844

02-343844

Vickers D10 Solenoid Valve
Item #102050775
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-343844
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Model No. DG5V-10-H-6C-2-T-M-U-C-10
Assembly Code None
Operation Pilot Operated
Actuator Type Solenoid
Gauge Port SAE-4
Housing Code None
Electrical Connection No Connector
Center Position P Blocked, A & B to T
Pressure Port Check Valve Pressure N/A
Pilot Pressure Code None
Valve Type Standard-Duty
Solenoid Energization Code None
Pressure [Max] 5000 psi
Mechanical Options Adjust Pilot Chokes on Both Ends
Pilot Drain Code T
Function 3-Position Spring Centered
Indicator Lights No
Gauge Ports Code None
Overrides Plain Override Solenoid Ends
Voltage & Frequency 220 VAC - 50 Hz
Spool Spring Arrangement Code C
Crossover P Blocked, A or B to T
Manual Override Plain Override
Rated Flow [Max] 290 gal/min
Electrical Options Code None
Pilot Pressure [Max] 3000 psi
Response Type Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Code None
Spool Code 6
Tank Port Rating 3000
Coil Type DIN 43650
Spool Control Modification Code 2
Solenoid Double
Seal Material Buna-N
Reducer Module Code None
Port T Pressure Rating 3000 psi
Coil Type Code U
Response Type Standard Response
Solenoid Indicator Lights Code None
Port Restrictor Plug Code None
AC/DC AC
Electrical Connector Code None
NFPA Size D10
Reducer Module N/A
EN Code None
Pilot/Drain External Pilot/Internal Drain
Manual Override Option Code None
Pilot Valve Type Code H
Port Restrictor Plugs None
Electrical Options None
Design No. 10
Surge Suppressor/Damper None
Coil Rating Code C
Pilot Valve Type CETOP 3, High Performance
Weight 100.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison