Vickers D10 Solenoid Valve
Item #101908323
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342986
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Reducer Module Code None
Coil Type DIN 43650
Rated Flow [Max] 290 gal/min
Seal Material Buna-N
Pilot Valve Type Code S
Assembly Code None
Manual Override Plain Override
Indicator Lights No
Model No. DG5V-10-S-8C-VM-U-D-10
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper Code None
Pressure Port Check Valve Code None
AC/DC AC
Pilot Drain Code None
Electrical Connection No Connector
Spool Spring Arrangement Code C
Gauge Port SAE-4
Solenoid Indicator Lights Code None
Valve Type Standard-Duty
Tank Port Rating 3000
Port Restrictor Plug Code None
Spool Control Modification Code None
Housing Code None
Response Type Code None
Solenoid Double
Solenoid Energization Code V
Reducer Module N/A
Pressure Port Check Valve Pressure N/A
Pilot Valve Type CETOP 3, Standard Performance
Port T Pressure Rating 3000 psi
Coil Type Code U
Manual Override Option Code None
Voltage & Frequency 220/240 VAC - 50/60 Hz
Port Restrictor Plugs None
Crossover All Ports Open, Restricted
Response Type Standard Response
Center Position P to T, A & B Blocked
Gauge Ports Code None
Electrical Connector Code None
NFPA Size D10
Electrical Options None
Function 3-Position Spring Centered
Actuator Type Solenoid
Pilot/Drain External Pilot/Internal Drain
Coil Rating Code D
Mechanical Options None
Pilot Pressure Code None
Operation Pilot Operated
EN Code None
Electrical Options Code None
Pressure [Max] 5000 psi
Pilot Pressure [Max] 3000 psi
Design No. 10
Spool Code 8
Surge Suppressor/Damper None
Weight 100.0 LB