Vickers D08 Solenoid Valve
Item #101908920
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342353
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Reducer Module Code None
Operation Pilot Operated
EN Code None
Crossover All Ports Open
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 175 gal/min
Tank Port Rating 5000
Solenoid Double
Indicator Lights Yes
No. of Stages Two Stage
NFPA Size D08
Fluid Cleanliness 19/17/14 micron
Solenoid Indicator Lights Code L
Port Restrictor Plugs None
Design No. 10
Gauge Ports Code None
Port T Pressure Rating 5000 psi
Manual Override Option Code None
Actuation Identification Solenoid A, Solenoid B
Pressure Port Check Valve Code None
Electrical Options None
Pressure [Max] 5000 psi
Response Type Code None
Electrical Connector Code T
Pressure Port Check Valve Pressure N/A
Overrides Plain Override Solenoid Ends
Leakage High Performance
Valve Type Standard-Duty
Pilot Valve Type CETOP 3, High Performance
Gauge Port SAE-4
Pilot Pressure Code E
Coil Type Code F
Body Material Ductile Iron
AC/DC AC
Surge Suppressor/Damper Code None
Pilot Valve Type Code H
Temperature Range [Min] -40 °F
Performance High Performance
Surge Suppressor/Damper None
Spool Spring Arrangement Code C
Response Type Standard Response
Manual Override Plain Override
Pilot Drain Code None
Temperature Range [Max] 230 °F
Coil Rating Code B
Function 3-Position Spring Centered
Mounting Subplate/Manifold Mount
Mechanical Options None
Housing Code W
Solenoid Energization Code None
Electrical Connection Wired Terminal Block
Center Position All Ports Open
Voltage & Frequency 110/120 VAC - 50/60 Hz
Compatible Fluids Petroleum Oil
Port Restrictor Plug Code None
Actuator Type Solenoid
Mechanical Options Code None
Seal Material Buna-N
Reducer Module No
Electrical Options Code None
Spool Control Modification Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Code 0
Spool Indicator Switch Code None
Model No. DG5V-8-H-0C-E-M-FTWL-B-10
Pilot/Drain External Pilot/External Drain
Weight 35.0 LB