- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Response Type Code | None |
Pilot Pressure Code | None |
No. of Stages | Two Stage |
AC/DC | AC |
Spool Indicator Switch Code | None |
Electrical Options | None |
Rated Flow [Max] | 175 gal/min |
Spool Code | 8 |
Solenoid Energization Code | V |
Overrides | Plain Override Solenoid Ends |
Indicator Lights | Yes |
Mechanical Options | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Center Position | P to T, A & B Blocked |
Housing Code | W |
Crossover | All Ports Open, Restricted |
Manual Override Option Code | None |
Surge Suppressor/Damper Code | None |
Compatible Fluids | Petroleum Oil |
Response Type | Standard Response |
Pilot/Drain | External Pilot/Internal Drain |
Coil Rating Code | B |
Spool Spring Arrangement Code | C |
Port T Pressure Rating | 5000 psi |
Surge Suppressor/Damper | None |
Pilot Valve Type | CETOP 3, Standard Performance |
Electrical Connection | Wired Terminal Block |
Pressure Port Check Valve Pressure | N/A |
Tank Port Rating | 5000 |
EN Code | None |
Design No. | 10 |
Operation | Pilot Operated |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Performance | Standard Performance |
Function | 3-Position Spring Centered |
Model No. | DG5V-8-S-8C-VM-FTWL-B-10 |
Pilot Valve Type Code | S |
Mounting | Subplate/Manifold Mount |
Pressure Port Check Valve Code | None |
NFPA Size | D08 |
Mechanical Options Code | None |
Gauge Ports Code | None |
Reducer Module Code | None |
Solenoid | Double |
Valve Type | Standard-Duty |
Port Restrictor Plug Code | None |
Manual Override | Plain Override |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Actuator Type | Solenoid |
Leakage | Standard Performance |
Port Restrictor Plugs | None |
Reducer Module | No |
Gauge Port | SAE-4 |
Pilot Drain Code | None |
Pressure [Max] | 5000 psi |
Fluid Cleanliness | 19/17/14 micron |
Body Material | Gray Iron |
Electrical Options Code | None |
Spool Control Modification Code | None |
Electrical Connector Code | T |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Coil Type Code | F |
Seal Material | Buna-N |
Solenoid Indicator Lights Code | L |
Weight | 35.0 LB |