Vickers D08 Solenoid Valve
Item #102171419
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-338305
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Solenoid Indicator Lights Code None
Actuator Type Solenoid
Gauge Ports Code None
Coil Rating Code B
Response Type Code None
EN Code None
Pressure [Max] 5000 psi
Valve Type Standard-Duty
Manual Override Plain Override
Seal Material Buna-N
Electrical Options None
Spool Indicator Switch Code None
Pilot Valve Type Code H
Gauge Port SAE-4
Solenoid Double
AC/DC AC
Surge Suppressor/Damper None
Pilot/Drain External Pilot/Internal Drain
Pilot Drain Code T
Housing Code W
Reducer Module Code None
Design No. 10
Pressure Port Check Valve Pressure 5 psi
Tank Port Rating 5000
Pressure Port Check Valve Code K
Spool Code 2
Overrides Plain Override Solenoid Ends
Center Position All Ports Blocked
Surge Suppressor/Damper Code None
Operation Pilot Operated
NFPA Size D08
Function 3-Position Spring Centered
Reducer Module N/A
Response Type Standard Response
Indicator Lights No
Coil Type Code F
Rated Flow [Max] 185 gal/min
Mechanical Options Code None
Manual Override Option Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plugs None
Spool Control Modification Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection No Connector
Pilot Valve Type CETOP 3, High Performance
Model No. DG5V-8-H-2C-T-K-M-FW-B-10
Electrical Connector Code None
Mechanical Options None
Electrical Options Code None
Port Restrictor Plug Code None
Port T Pressure Rating 5000 psi
Pilot Pressure Code None
Crossover All Ports Blocked
Spool Spring Arrangement Code C
Solenoid Energization Code None
Weight 35.0 LB