Skip to content Skip to navigation menu
Vickers by Danfoss02-337583

02-337583

Vickers D08 Solenoid Valve
Item #102199570
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337583
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Do not over-tighten mounting screw. The PU-E cord should not be grouped with any other wires or cords. For applications with PU-E wires over 6' long, or particularly noisy environments, a shielded cable is recommended. Connect the shield to the common ter
Reducer Module Code None
Compatible Fluids Petroleum Oil
Valve Type Standard-Duty
Pilot Pressure Code None
Gauge Port SAE-4
Performance High Performance
Seal Material Buna-N
Coil Type ISO 4400 (Din 43650) Connector
Response Type Standard Response
Housing Code None
Port T Pressure Rating 5000 psi
Port Restrictor Plugs None
Surge Suppressor/Damper None
No. of Stages Two Stage
Spool Code 33
Function 3-Position Spring Centered
Tank Port Rating 5000
Pressure [Max] 5000 psi
Coil Rating Code B
Overrides Plain Override Solenoid Ends
Model No. DG5V-8-H-33C-M-U-B-10
Rated Flow [Max] 175 gal/min
Fluid Cleanliness 19/17/14 micron
Electrical Connector Code None
Mechanical Options Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Crossover P Blocked, A or B to T
NFPA Size D08
Reducer Module No
Pressure Port Check Valve Code None
Design No. 10
Pilot Valve Type CETOP 3, High Performance
Response Type Code None
Pilot Valve Type Code H
Mechanical Options None
Gauge Ports Code None
AC/DC AC
Coil Type Code U
Spool Control Modification Code None
Electrical Options None
Spool Indicator Switch Code None
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code C
Manual Override Plain Override
Pilot Drain Code None
Actuator Type Solenoid
Port Restrictor Plug Code None
Manual Override Option Code None
Indicator Lights No
Leakage Standard Performance
Electrical Options Code None
Pressure Port Check Valve Pressure N/A
Mounting Subplate/Manifold Mount
Operation Pilot Operated
Surge Suppressor/Damper Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Solenoid Double
Electrical Connection No Connector
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position P Blocked, A & B to T
EN Code None
Pilot/Drain Internal Pilot/External Drain
Body Material Gray Iron
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison