Vickers D03 Solenoid Valve

02-336829

Vickers D03 Solenoid Valve
Item #101912656
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • For directing and stopping flow at any point in a hydraulic system. Its primary function is to determine the direction of fluid flow in a work cylinder or control the direction of rotation of a fluid motor. Port connections are made by mounting the valve on a subplate or manifold. The valve has wet armature type solenoids. It is derived from the standard model series DG4V-3S-60.

features

  • Tank line can withstand pressures up to 210 bar (3,000 psi)
  • High thermal shock and impact resistance due to new coil design
  • Minimal pressure drop
  • Scratch-proof override seals
  • Multiple electrical connections
  • High reliability

compliances

  • 0
Pilot/Drain None
Coil Rating Code H
Mounting Subplate/Manifold Mount
Temperature Range [Max] 158 °F
Coil Type Code U
Valve Type Standard-Duty for Mobile Equipment
Manual Override Plain Override
Rated Flow [Max] 10 gal/min
Function Code 6
Coil Type ISO 4400
Reducer Module No
Seal Material Buna-N
Spool Shift Timing N/A
Port Restrictor Plug Code None
AC/DC DC
Watt Rating 30 W
Leakage Standard Performance
Response Type Standard Response
Housing Code None
Body Material Gray Iron
Spool Spring Arrangement Code C
Voltage & Frequency 24 VDC
Compatible Fluids Petroleum Oil
Overrides No Overrides
Port Restrictor Plugs None
Actuation Identification Solenoid A, Solenoid B
Solenoid Double
Electrical Options None
Center Position P Blocked, A & B to T
Temperature Range [Min] -4 °F
Solenoid Indicator Lights Code None
Indicator Lights No
Surge Suppressor/Damper None
Electrical Connector Code None
Response Time 40 to 60 ms
Crossover P Blocked, A or B to T
Model No. DG4V-3S-6C-H-M-U-H7-60-EN490
Spool Indicator Switch Code None
Electrical Connection DIN 43650
Pilot Valve Type N/A
Port T Code 7
Operation Solenoid Operated
Manual Override Option Code H
Cycle Rate [Max] N/A
Fluid Cleanliness 19/17/14 micron
Tank Port Rating 1450
Port T Pressure Rating 3000 psi
Solenoid Energization Code None
Surge Suppressor/Damper Code None
NFPA Size D03
Actuator Type Solenoid
Pressure [Max] 5000 psi
Performance Standard Performance
Solenoid Code H
Function 3-Position Spring Centered
Pressure Port Check Valve Pressure N/A
Spool Code 6
No. of Stages Single Stage
Design No. 60
Mechanical Options None
EN Code EN490
Weight 5.0 LB