- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Manual Override | Plain Override |
| Seal Material | Buna-N |
| Electrical Options Code | None |
| Pilot Drain Code | T |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| No. of Stages | Two Stage |
| Spool Control Modification Code | None |
| Rated Flow [Max] | 175 gal/min |
| Compatible Fluids | Petroleum Oil |
| Pressure [Max] | 5000 psi |
| Fluid Cleanliness | 19/17/14 micron |
| Solenoid | Double |
| Spool Code | 8 |
| Manual Override Option Code | None |
| Pilot Pressure Code | None |
| Design No. | 10 |
| Surge Suppressor/Damper Code | None |
| NFPA Size | D08 |
| Model No. | DG5V-8-S-8C-T-S-VM-FTWL-B-10 |
| Port Restrictor Plug Code | None |
| Spool Spring Arrangement Code | C |
| Electrical Options | None |
| Port Restrictor Plugs | None |
| Temperature Range [Max] | 230 °F |
| Performance | Standard Performance |
| Coil Rating Code | B |
| Body Material | Ductile Iron |
| Solenoid Energization Code | V |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Electrical Connector Code | T |
| Valve Type | Standard-Duty |
| Response Type | Standard Response |
| Indicator Lights | Yes |
| AC/DC | AC |
| Operation | Pilot Operated |
| Pressure Port Check Valve Pressure | 75 psi |
| Center Position | P to T, A & B Blocked |
| Mechanical Options Code | None |
| Tank Port Rating | 5000 |
| Gauge Port | SAE-4 |
| Housing Code | W |
| Pressure Port Check Valve Code | S |
| Electrical Connection | Wired Terminal Block |
| Leakage | Standard Performance |
| Response Type Code | None |
| Temperature Range [Min] | -40 °F |
| Overrides | Plain Override Solenoid Ends |
| Spool Indicator Switch Code | None |
| Pilot Valve Type Code | S |
| Gauge Ports Code | None |
| Surge Suppressor/Damper | None |
| Reducer Module Code | None |
| Mechanical Options | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Function | 3-Position Spring Centered |
| Solenoid Indicator Lights Code | L |
| Reducer Module | No |
| Crossover | All Ports Open, Restricted |
| Pilot/Drain | External Pilot/Internal Drain |
| Port T Pressure Rating | 5000 psi |
| Actuation Identification | Solenoid A, Solenoid B |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Coil Type Code | F |
| Mounting | Subplate/Manifold Mount |
| Actuator Type | Solenoid |
| EN Code | None |
| Weight | 35.0 LB |