Vickers by Danfoss02-336038

02-336038

Vickers D03 Solenoid Valve
Item #101914109
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-336038
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • For directing and stopping flow at any point in a hydraulic system. Its primary function is to determine the direction of fluid flow in a work cylinder or control the direction of rotation of a fluid motor. Port connections are made by mounting the valve on a subplate or manifold. The valve has wet armature type solenoids. It is derived from the standard model series DG4V-3S-60.

features

  • Tank line can withstand pressures up to 210 bar (3,000 psi)
  • High thermal shock and impact resistance due to new coil design
  • Minimal pressure drop
  • Scratch-proof override seals
  • Multiple electrical connections
  • High reliability

compliances

  • 0
Rated Flow [Max] 10.5 gal/min
Spool Indicator Switch Code None
Coil Type Code U1
Voltage & Frequency 12 VDC
Response Type Standard Response
EN Code EN490
AC/DC DC
Pilot/Drain None
Spool Spring Arrangement Code C
Function 3-Position Spring Centered
Pilot Valve Type N/A
Electrical Connector Code None
Electrical Options None
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Model No. DG4V-3S-6C-H-M-U1-G7-60-EN490
Mechanical Options None
Design No. 60
Solenoid Double
Crossover P Blocked, A or B to T
Surge Suppressor/Damper Code None
Port Restrictor Plug Code None
Port T Code 7
Overrides No Overrides
Manual Override Option Code H
Spool Shift Timing N/A
Pressure [Max] 5075 psi
Tank Port Rating 3000
Solenoid Energization Code None
Port Restrictor Plugs None
Coil Type Connector Fitted
Surge Suppressor/Damper None
Reducer Module N/A
NFPA Size D03
Cycle Rate [Max] N/A
Valve Type Standard-Duty for Mobile Equipment
Spool Code 6
Housing Code None
Function Code 6
Solenoid Code G
Coil Rating Code G
Pressure Port Check Valve Pressure N/A
Seal Material Buna-N
Electrical Connection Connector Fitted
Center Position P Blocked, A & B to T
Port T Pressure Rating 3000 psi
Operation Solenoid Operated
Indicator Lights No
Weight 5.0 LB