Vickers D08 Solenoid Valve
Item #102084205
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-330433
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pilot/Drain External Pilot/Internal Drain
Spool Spring Arrangement Code N
Reducer Module No
Port Restrictor Plugs None
Mechanical Options None
Tank Port Rating 5000
Pilot Valve Type Code S
Port T Pressure Rating 5000 psi
Gauge Ports Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Response Type Standard Response
Pilot Drain Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Coil Type Code F
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights Yes
Electrical Connection Wired Terminal Block
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
NFPA Size D08
Rated Flow [Max] 175 gal/min
Center Position All Ports Open Over Tapers
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Surge Suppressor/Damper None
Spool Code 9
Mechanical Options Code None
Pilot Valve Type CETOP 3, Standard Performance
Actuator Type Solenoid
Seal Material Buna-N
Housing Code W
Electrical Options None
Electrical Connector Code T
Manual Override Option Code None
Surge Suppressor/Damper Code None
Operation Pilot Operated
Electrical Options Code None
Reducer Module Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
EN Code None
Coil Rating Code B
Port Restrictor Plug Code None
Pressure [Max] 5000 psi
Leakage Standard Performance
Spool Control Modification Code None
Solenoid Double
Manual Override Plain Override
Design No. 10
Body Material Gray Iron
Gauge Port SAE-4
Solenoid Indicator Lights Code L
No. of Stages Two Stage
Model No. DG5V-8-S-9N-M-FTWL-B-10
Pilot Pressure Code None
Valve Type Standard-Duty
Crossover All Ports Open
Performance Standard Performance
Function 3-Position Detented
Pressure Port Check Valve Code None
Solenoid Energization Code None
Overrides Plain Override Solenoid Ends
Response Type Code None
AC/DC AC
Compatible Fluids Petroleum Oil
Weight 35.0 LB