Vickers by Danfoss02-329256

02-329256

Vickers D08 Solenoid Valve
Item #101979708
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329256
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • If the drive has more than three pulleys, every other pulley should be flanged
Overrides Plain Override Solenoid Ends
Center Position P & B Blocked, A to T
Solenoid Energization Code None
Actuation Identification Solenoid A, Solenoid B
Crossover All Ports Blocked, or P & B Blocked, A to T
Solenoid Indicator Lights Code L
EN Code None
Gauge Ports Code None
Leakage Standard Performance
Spool Spring Arrangement Code C
Actuator Type Solenoid
Indicator Lights Yes
Function 3-Position Spring Centered
Gauge Port SAE-4
Design No. 10
NFPA Size D08
Pressure Port Check Valve Pressure N/A
Port Restrictor Plug Code None
Spool Control Modification Code None
Manual Override Option Code None
Response Type Standard Response
Reducer Module No
Tank Port Rating 5000
Voltage & Frequency 110/120 VAC - 50/60 Hz
Compatible Fluids Petroleum Oil
Electrical Options Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Double
Pilot/Drain External Pilot/Internal Drain
Manual Override Plain Override
Temperature Range [Max] 230 °F
Pilot Drain Code T
Seal Material Buna-N
Housing Code W
Response Type Code None
Port Restrictor Plugs None
No. of Stages Two Stage
Model No. DG5V-8-S-3C-T-M-FTWL-B-10
Mechanical Options None
Pressure Port Check Valve Code None
Rated Flow [Max] 175 gal/min
Performance Standard Performance
Electrical Connection Wired Terminal Block
Reducer Module Code None
Port T Pressure Rating 5000 psi
Temperature Range [Min] -40 °F
Coil Type Code F
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
AC/DC AC
Pilot Valve Type Code S
Pressure [Max] 5000 psi
Mounting Subplate/Manifold Mount
Pilot Valve Type CETOP 3, Standard Performance
Surge Suppressor/Damper Code None
Operation Pilot Operated
Spool Code 3
Valve Type Standard-Duty
Surge Suppressor/Damper None
Mechanical Options Code None
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Body Material Ductile Iron
Electrical Options None
Electrical Connector Code T
Pilot Pressure Code None
Coil Rating Code B
Weight 35.0 LB