Vickers by Danfoss02-329199

02-329199

Vickers D08 Solenoid Valve
Item #101971267
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329199
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Standard, QD-style HTD sprockets may not have the torque capacity for the higher rated HT150 belts.
Crossover All Ports Open, Restricted
Pilot/Drain Internal Pilot/Internal Drain
Gauge Port SAE-4
Coil Rating Code B
Mechanical Options Adjust Pilot Chokes on Both Ends
Actuation Identification Solenoid A, Solenoid B
Port Restrictor Plug Code None
Actuator Type Solenoid
Tank Port Rating 5000
Spool Indicator Switch Code None
Function 3-Position Spring Centered
Spool Control Modification Code 2
Coil Type Code F
Performance Standard Performance
Leakage Standard Performance
Pressure Port Check Valve Code S
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Spring Arrangement Code C
Pilot Pressure Code None
Electrical Connection No Connector
EN Code None
Manual Override Option Code None
Mechanical Options Code None
Seal Material Buna-N
Indicator Lights No
Pressure [Max] 5000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 5000 psi
Overrides Plain Override Solenoid Ends
Housing Code W
Surge Suppressor/Damper Code None
Electrical Options None
Center Position P to T, A & B Blocked
Pilot Valve Type Code S
Response Type Standard Response
NFPA Size D08
Surge Suppressor/Damper None
Temperature Range [Min] -40 °F
Body Material Ductile Iron
Solenoid Energization Code V
Spool Code 8
Operation Pilot Operated
Fluid Cleanliness 19/17/14 micron
No. of Stages Two Stage
Model No. DG5V-8-S-8C-2-T-S-VM-FW-B-10
Pilot Drain Code T
Rated Flow [Max] 175 gal/min
Solenoid Indicator Lights Code None
Temperature Range [Max] 230 °F
Design No. 10
Reducer Module No
Solenoid Double
Manual Override Plain Override
Pilot Valve Type CETOP 3, Standard Performance
Valve Type Standard-Duty
Port Restrictor Plugs None
AC/DC AC
Mounting Subplate/Manifold Mount
Gauge Ports Code None
Compatible Fluids Petroleum Oil
Pressure Port Check Valve Pressure 75 psi
Reducer Module Code None
Electrical Options Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Response Type Code None
Electrical Connector Code None
Weight 35.0 LB