Vickers D08 Solenoid Valve
Item #101975665
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329198
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Not intended for use in most cyclic applications or high speed engagement
  • Tooth clutches are normally engaged when stationary
Center Position P to T, A & B Blocked
Mechanical Options Code None
Solenoid Double
Rated Flow [Max] 185 gal/min
Port T Pressure Rating 5000 psi
Pilot Drain Code None
Valve Type Standard-Duty
Solenoid Indicator Lights Code None
Crossover All Ports Open, Restricted
Manual Override Option Code None
Manual Override Plain Override
Response Type Standard Response
Solenoid Energization Code V
Pilot Valve Type Code S
Pilot Valve Type CETOP 3, Standard Performance
Electrical Connector Code None
Gauge Port SAE-4
Pressure [Max] 5000 psi
Pilot Pressure Code None
Function 3-Position Spring Centered
AC/DC AC
Mechanical Options Adjust Pilot Chokes on Both Ends
Spool Spring Arrangement Code C
Gauge Ports Code None
Reducer Module Code None
Actuator Type Solenoid
Spool Control Modification Code 2
Coil Type Code F
Indicator Lights No
Operation Pilot Operated
Spool Code 8
Housing Code W
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Pressure Port Check Valve Code S
Design No. 10
Coil Rating Code B
Pilot/Drain External Pilot/Internal Drain
Model No. DG5V-8-S-8C-2-S-VM-FW-B-10
Response Type Code None
Port Restrictor Plugs None
Reducer Module N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Voltage & Frequency 110/120 VAC - 50/60 Hz
NFPA Size D08
EN Code None
Seal Material Buna-N
Electrical Options None
Pressure Port Check Valve Pressure 75 psi
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
Electrical Connection No Connector
Overrides Plain Override Solenoid Ends
Electrical Options Code None
Tank Port Rating 5000
Weight 35.0 LB